Skip to main content

Hue Bridge EUVDEUVD-2026-12157

| CVE-2026-3556 HIGH
Heap-based Buffer Overflow (CWE-122)
2026-03-13 zdi
8.8
CVSS 3.0 · NVD
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Connect to local network
  2. Exploit
    Send crafted HomeKit Pair-Setup request
  3. Execution
    Overflow heap buffer in hk_hap_pair_storage_put
  4. Impact
    Execute arbitrary code on Philips Hue Bridge

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Heap buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Network-adjacent attacker on same local network segment as Philips Hue Bridge. HomeKit Pair-Setup service must be accessible. No authentication required. Default installations vulnerable.

Impact

The CVSS 3.0 score of 8.8 reflects high severity with attack vector 'Adjacent' (AV:A), low complexity (AC:L), no privileges required (PR:N), and high impact across confidentiality, integrity, and availability. However, the real-world risk requires nuanced assessment: the attack requires local network access, limiting exposure compared to internet-facing vulnerabilities. No EPSS score is provided, and the vulnerability is not listed in CISA KEV, suggesting no known active exploitation. The ZDI advisory (ZDI-26-154) indicates this was responsibly disclosed. While the technical impact is severe (unauthenticated RCE), the adjacent network requirement significantly constrains the attack surface to trusted network environments. This is a priority for organizations with Philips Hue deployments but not a critical internet-wide threat.

Exploit ScenarioDerived

An attacker on the same local network as the Philips Hue Bridge (e.g., compromised IoT device, malicious insider, or attacker on guest WiFi with access to the IoT VLAN) could send specially crafted HomeKit pair-setup requests to trigger the buffer overflow. Since no authentication is required and attack complexity is low, the attacker could potentially automate this attack. Successful exploitation would grant code execution with the privileges of the HomeKit service, potentially allowing full control over the home automation system, access to other network devices, or using the bridge as a persistent foothold in the network. No public proof-of-concept is mentioned, but the detailed function name suggests the vulnerability details are well understood.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 13, 2026

Critical heap-based buffer overflow vulnerability in Philips Hue Bridge's HomeKit implementation that allows network-adjacent attackers to execute arbitrary code without authentication. The vulnerability affects all versions of Philips Hue Bridge (CPE indicates no version restriction) and stems from improper input validation in the hk_hap_pair_storage_put function. No active exploitation (not in KEV) or EPSS score is reported, but the high CVSS score (8.8) and RCE capability make this a significant threat for local network attackers.

RemediationAI

No patch information or vendor advisory is currently available based on the provided references. The only reference points to the ZDI advisory (https://www.zerodayinitiative.com/advisories/ZDI-26-154/), which typically indicates responsible disclosure but may not include patch details. Users should monitor Philips' security advisories for firmware updates. As a temporary mitigation, consider: 1) Isolating Philips Hue Bridge devices on a separate network segment, 2) Restricting network access to the device, 3) Disabling HomeKit integration if not required, 4) Implementing network-level access controls to limit who can reach the device on the local network.

Affected VersionsENISA

Hue Bridge 1.73.1973146020

Affected Packages

euvd hue_bridge no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability occurs in the HomeKit Accessory Protocol (HAP) implementation on Philips Hue Bridge devices, specifically in the pair-setup process handled by the hk_hap_pair_storage_put function. The CWE-122 classification indicates a heap-based buffer overflow where user-supplied data is copied to a fixed-length heap buffer without proper bounds checking. Based on the CPE string (cpe:2.3:a:philips:hue_bridge:*:*:*:*:*:*:*:*), all versions of the Philips Hue Bridge software are affected. The vulnerability allows code execution in the context of the HomeKit service, which likely runs with elevated privileges to manage home automation functions.

Know when Hue Bridge gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 8.8 HIGH
AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326.

Executive ViewAI

Why It Matters

CVE-2026-3556 is a critical remote code execution vulnerability in Philips Hue Bridge devices that allows attackers on the same network to gain unauthorized control without authentication. Organizations using Philips Hue smart lighting systems are at risk of system compromise, potential lateral network movement, and operational disruption, as no patch is currently available.

Business Impact: High
Compensating Controls

Isolate Philips Hue Bridge devices on a separate network segment with firewall rules restricting access from general user networks; disable HomeKit protocol support if the feature is not required for operations; implement strict network access controls limiting connections to authorized administrative systems only; monitor for suspicious activity on IoT network segments; consider replacing affected devices with vendors that provide timely security updates.

Threat Intelligence Overview

EPSS Score
0.1%
Top 78% exploitable
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact
High

Priority Score

44
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +44
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A heap overflow occurs when a program writes data beyond the bounds of a buffer allocated in the heap memory region.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy