Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessCraft malicious V7 file
-
DeliveryDeliver to HMI engineer via email or shared project
-
ExploitVictim opens file in V-SFT
-
ExecutionOut-of-bounds read in VS6ComFile!load_gr_item
-
ImpactInformation disclosure or arbitrary code execution
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, read limits
MITRE ATT&CK
1 technique across 1 tactic: Collection The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires a user to open a maliciously crafted V7 file in Fuji Electric V-SFT on the local workstation (CVSS UI:A, AV:L). There is no network-facing attack surface and no authentication requirement beyond local user context (PR:N); the attacker instead needs a delivery/social-engineering step to get the crafted file in front of a V-SFT operator. Limiting factors: the victim must actively open the attacker-supplied file, the attacker needs it to reach an engineering workstation running V-SFT, and impact is confined to that system (SC/SI/SA:N) - there is no automated or self-propagating path. |
| Impact | This is a file-parsing memory-safety flaw (CWE-125 out-of-bounds read) in Fuji Electric V-SFT's VS6ComFile!load_gr_item routine, triggered when a user opens a crafted V7 file. The supplied CVSS 4.0 vector (AV:L/AC:L/AT:N/PR:N/UI:A, VC:H/VI:H/VA:H, score 8.4) describes a local, low-complexity attack requiring active user interaction but no privileges, with high confidentiality, integrity and availability impact to the vulnerable system only (SC/SI/SA:N). This is a client-side engineering-workstation risk, not a remotely reachable service: an attacker cannot trigger it without getting an operator to open a malicious file, which materially lowers real-world likelihood versus a network-exploitable bug. No EPSS score was provided, the CVE is not in CISA KEV, and no public exploit or PoC reference is present in the input - so there is no signal of active or imminent mass exploitation. The vuln.today decision label is 'this_week', indicating elevated-but-not-emergency priority. Signals are broadly consistent: high technical impact is offset by the local vector and required user interaction. Note the stated outcome spans 'information exposure OR arbitrary code execution' from a single OOB read primitive - the path to reliable code execution is not detailed in the available sources and should be treated as the vendor's worst-case rather than a confirmed capability. |
| Exploit ScenarioDerived | An attacker crafts a malicious V7 project/screen file and delivers it to an HMI engineer or integrator (via email, a shared project repository, or a compromised supplier), relying on the fact that opening such files in V-SFT is routine. When the engineer opens the file, the out-of-bounds read in load_gr_item is triggered, leaking process memory or, in the worst case claimed by the vendor, executing attacker-controlled code on the engineering workstation. No public exploit identified at time of analysis; the attack requires user interaction (opening the file) and only local access to that workstation. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 26, 2026
Out-of-bounds read in Fuji Electric V-SFT's VS6ComFile!load_gr_item routine can expose memory contents or enable arbitrary code execution when an operator opens a crafted V7 file. The attack is local and requires user interaction: an attacker must deliver a malicious V7 file and convince a V-SFT user to open it. No public exploit identified at time of analysis, and the issue is not confirmed as actively exploited (CISA KEV).
RemediationAI
No vendor-released patch is identified at time of analysis. Consult the vendor advisory at https://felib.fujielectric.co.jp/en/M10010/M20060/document_detail/5d9dd71d-9494-41a4-aa5c-8e6b8b21066b?region=en-glb and the JVN entry at https://jvn.jp/en/vu/JVNVU96549652/ for current fixed versions and vendor guidance. Because exploitation requires opening a crafted V7 file, restrict V7 file intake on V-SFT engineering workstations to trusted sources and isolate those systems from untrusted file exchange; the trade-off is reduced convenience for receiving project files. Running V-SFT under a low-privilege account limits post-exploitation impact but does not prevent the parser flaw.
Affected VersionsENISA
Affected Packages
Source: OSV (Open Source Vulnerabilities)
Affects your stack
Affects 1 package in euvd
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The issue is classified as CWE-125 (out-of-bounds read) in the V-SFT file-parsing code path VS6ComFile!load_gr_item. The CPE identifies Fuji Electric V-SFT as the affected product, with a wildcard version field. The trigger described in the supplied data is opening a crafted V7 file in the product; the specific malformed structure within that file and the exact parsing path beyond load_gr_item are not described in the available sources. The CVSS 4.0 vector is AV:L/AC:L/AT:N/PR:N/UI:A, reflecting a local attack that requires the user to open the crafted file. The description states the out-of-bounds read may lead to information exposure or arbitrary code execution, while the independent assessment rates confidentiality, integrity and availability impact as high on the local system only, with no subsequent-system impact (SC/SI/SA:N).
Know when V Sft gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Local file-open trigger gives AV:L and UI:R; no privileges needed so PR:N; memory corruption yields potential high C/I/A on the unchanged scope of the workstation.
Primary rating from Vendor (jpcert).
CVSS VectorVendor: jpcert
Lifecycle Timeline
2DescriptionCVE.org
V-SFT provided by FUJI ELECTRIC CO., LTD. contains an out-of-bounds read vulnerability in VS6ComFile!load_gr_item. Opening a crafted V7 file may lead to information exposure or arbitrary code execution on the affected product.
Executive ViewAI
A high-severity out-of-bounds read vulnerability in Fuji Electric V-SFT's file loading routine affects operators who open V7 project files. If exploited, this could lead to memory disclosure or arbitrary code execution on engineering workstations, potentially compromising intellectual property and enabling lateral movement within industrial control environments. Leadership should prioritize mitigation because the vendor has not released a patch and the product is critical for HMI/SCADA configuration.
No vendor-released patch identified at time of analysis. Interim mitigations include: restricting V7 file handling to trusted sources, applying file sandboxing/CDR, enforcing least privilege and application allowlisting, segmenting engineering workstations, and monitoring for anomalous process behavior.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
Opening a crafted V7 project file in Fuji Electric V-SFT (the HMI screen-configuration and programming software, listed
Out-of-bounds read in Fuji Electric V-SFT can be triggered when a user opens a crafted V7 project file, potentially expo
Opening a crafted V7 project file in Fuji Electric/Hakko V-SFT can cause an out-of-bounds read in VS6EditData!CDataRomEr
Opening a crafted V7 project file in Fuji Electric V-SFT can trigger an out-of-bounds read in the macro-command check pa
Opening a crafted V7 project file in Fuji Electric's V-SFT screen-creation/engineering software can drive an out-of-boun
An out-of-bounds write in Fuji Electric's V-SFT screen-creation software (also published under Hakko Electronics) is tri
Stack-based buffer overflow in Fuji Electric/Hakko Electronics V-SFT versions through 6.2.10.0 enables arbitrary code ex
Stack-based buffer overflow in Fuji Electric/HAKKO Electronics V-SFT automation software (versions ≤6.2.10.0) allows arb
Out-of-bounds read in Fuji Electric V-SFT 6.2.10.0 and earlier allows local attackers to disclose sensitive information
Out-of-bounds read in Fuji Electric V-SFT 6.2.10.0 and earlier allows local attackers to extract sensitive memory conten
Out-of-bounds read in Fuji Electric V-SFT industrial HMI software (versions ≤6.2.10.0) enables local attackers to disclo
Access of uninitialized pointer vulnerability exists in the simulator module contained in the graphic editor 'V-SFT' ver
EUVD-2026-109626
GHSA-c4cq-3h3m-p6ph
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB