Skip to main content

Sge Plc1000 Firmware EUVDEUVD-2025-200236

| CVE-2025-11780 CRITICAL
Classic Buffer Overflow (CWE-120)
2025-12-02 cve-coordination@incibe.es
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A06:2021 - Vulnerable and Outdated Components
ASVS 5.0
V15 - Secure Coding and Architecture Buffer copy size validation
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

Successful exploitation can lead to arbitrary code execution, denial of service, or privilege escalation depending on the memory layout and protections in place. With a CVSS score of 9.8 (CRITICAL), this represents a critical risk.

Exploit ScenarioDerived

An attacker sends an oversized input to a vulnerable function, overwriting the return address on the stack to redirect execution to attacker-controlled shellcode.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Mar 15, 2026

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter.

Earlier versions of this analysis (1)
v1 Mar 15, 2026 - 14:04 CVSS 9.8

RemediationAI

Use memory-safe languages or bounds-checked functions. Enable ASLR, DEP/NX, and stack canaries. Apply vendor patches promptly.

Affected VersionsENISA

Circutor 9.0.2

Affected Packages

euvd circutor no fix

Source: OSV (Open Source Vulnerabilities)

Affects your stack

Affects 1 package in euvd

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

A buffer overflow occurs when data written to a buffer exceeds its allocated size, potentially overwriting adjacent memory and corrupting program state. This vulnerability is classified as Classic Buffer Overflow (CWE-120).

Know when Sge Plc1000 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Executive ViewAI

Why It Matters

A critical stack-based buffer overflow vulnerability (CVE-2025-11780) affects Circutor SGE-PLC1000/SGE-PLC50 devices running version 9.0.2, allowing remote attackers to execute arbitrary code with a 9.8 CVSS score. Organizations using these industrial control systems face potential operational disruption, data theft, and loss of system availability if exploited.

Business Impact: Severe
Compensating Controls

Implement network segmentation to isolate affected Circutor devices from untrusted networks; deploy Web Application Firewall (WAF) rules to validate and limit the 'meter' parameter input length; restrict administrative access to the showMeterReport() function via authentication controls; disable the meter reporting feature if non-essential to operations; monitor network traffic for exploitation attempts targeting the vulnerable function; establish incident response procedures for potential compromise.

Threat Intelligence Overview

EPSS Score
0.1%
Top 80% exploitable
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.1%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Out-of-Cycle
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Very High

Priority Score

49
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

CVE-2025-11785 CRITICAL
9.8 Dec 02

Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' functi

CVE-2025-11778 CRITICAL
9.8 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely

CVE-2021-33841 CRITICAL
9.8 Jun 09

SGE-PLC1000 device, in its 0.9.2b firmware version, does not handle some requests correctly, allowing a remote attacker

CVE-2025-11779 CRITICAL
9.4 Dec 02

Stack-based buffer overflow in the Circutor SGE-PLC1000 and SGE-PLC50 power line communication devices running firmware

CVE-2021-33842 HIGH
8.8 Jun 09

Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an

CVE-2025-11781 HIGH
8.6 Dec 02

Hardcoded cryptographic key exposure in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 lets an attacker who has loca

CVE-2025-11787 HIGH
8.5 Dec 02

Authenticated command injection in Circutor SGE-PLC1000 and SGE-PLC50 gateways running firmware 9.0.2 lets a low-privile

CVE-2025-11783 HIGH
8.5 Dec 02

A stack-based buffer overflow in the AddEvent() function of Circutor SGE-PLC1000 and SGE-PLC50 power-line communication

CVE-2025-11786 HIGH
8.5 Dec 02

Authenticated adjacent-network attackers can execute arbitrary shell commands on Circutor SGE-PLC1000 and SGE-PLC50 devi

CVE-2025-11784 HIGH
8.5 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 smart-grid PLC concentrators running firmware v9.0.2 a

CVE-2025-11782 HIGH
8.5 Dec 02

Stack-based buffer overflow in Circutor SGE-PLC1000 and SGE-PLC50 firmware v9.0.2 allows authenticated attackers on an a

CVE-2025-11788 HIGH
8.5 Dec 02

Heap-based buffer overflow in the management interface of Circutor SGE-PLC1000 and SGE-PLC50 concentrators running firmw

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy