Johnson Controls ICS CVE-2025-61739

HIGH
Reusing a Nonce, Key Pair in Encryption (CWE-323)
2025-12-22 productsecurity@jci.com
7.2
CVSS 4.0 · Vendor: jci
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain adjacent-network foothold
  2. Delivery
    Passively capture encrypted packets
  3. Exploit
    Exploit reused nonce (CWE-323)
  4. Execution
    Replay or decrypt traffic
  5. Impact
    Disclose data or forge/repeat messages

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A04:2025 - Cryptographic Failures
ASVS 5.0
V11 - Cryptography Nonce/key pair uniqueness
Exploitation Conditions

Exploitation requires the attacker to occupy an adjacent/local network position (CVSS AV:A) relative to the affected Johnson Controls device so that encrypted traffic can be intercepted or injected - this cannot be performed remotely over the internet without such access. Given PR:N and UI:N, no authentication or victim interaction is needed once the attacker is on the network. The core flaw is cryptographic nonce reuse (CWE-323) in the product's encrypted communications, which permits replaying previously captured packets and/or decrypting captured ciphertext. The primary limiting factor is the adjacency requirement (same L2 segment/local network); the specific affected product, version, and whether any particular communication mode or feature must be in use are not specified in the provided data and should be confirmed against the Johnson Controls advisory and CISA ICSA-25-350-02.

Impact

This is a genuine but bounded risk, best characterized as a HIGH-severity (CVSS 4.0 base 7.2) cryptographic weakness whose real-world exploitability is constrained by network positioning rather than configuration. The CVSS vector reports adjacent-network access (AV:A), low complexity (AC:L), no privileges (PR:N) and no user interaction (UI:N), with impact weighted toward integrity (VI:H) over confidentiality (VC:L) and availability (VA:L) - consistent with CWE-323 (nonce reuse) enabling both replay (integrity) and limited packet decryption (confidentiality). Signals are coherent and point toward MODERATE priority: EPSS is low at 0.19% (8th percentile), there is no CISA KEV listing and no public exploit identified, so there is no evidence of active or widespread exploitation. No SSVC decision data was provided in the input. The AV:A requirement is the dominant limiting factor - an attacker must already be on the same local/adjacent network segment to capture traffic, which rules out remote internet-based mass exploitation and makes this most relevant to insider, lateral-movement, or physically-proximate threat models typical of ICS/building-automation environments. Net: prioritize patching for exposed or flat OT networks, but this is not an internet-facing drop-everything emergency given the adjacency constraint and low EPSS.

Exploit ScenarioDerived

An attacker with a foothold on the same local/adjacent network segment as the affected Johnson Controls device passively captures its encrypted traffic. Because the same nonce is reused during encryption (CWE-323), the attacker can replay captured packets to repeat prior commands/transactions or perform cryptanalysis to decrypt sensitive captured data. No public proof-of-concept exploit was identified in the provided intelligence, and exploitation requires adjacent-network access rather than remote reachability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 19, 2026

Nonce reuse in Johnson Controls ICS encrypted communications lets unauthenticated attackers on an adjacent network replay captured packets or decrypt intercepted traffic, with high integrity impact and limited confidentiality and availability impact. The supplied data does not name the exact affected device models or firmware versions, so scope must be confirmed against the Johnson Controls advisory and CISA ICSA-25-350-02. No public exploit code or CISA KEV entry was identified at time of analysis, and EPSS is 0.19%.

RemediationAI

No vendor-released patch or fixed firmware version is identified in the supplied data; check the Johnson Controls advisory (https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories) and CISA ICSA-25-350-02 (https://www.cisa.gov/news-events/ics-advisories/icsa-25-350-02) for the current fixed release and upgrade instructions. Because exploitation requires adjacency, isolate affected devices on dedicated VLANs or segments with strict ACLs and prevent untrusted hosts from sharing the same Layer 2 domain; the trade-off is added management complexity and possible disruption of legitimate local integrations. If the affected encrypted communication mode can be disabled or wrapped in a separately validated encrypted tunnel, do so after compatibility testing; the trade-off is loss of functionality or performance overhead. Monitor for replay or anomalous encrypted traffic and restrict physical and network access to the device segment.

Affected ProductsAI

Exact affected products and versions are not specified in the supplied data. The CVE is attributed to Johnson Controls and appears in CISA ICS advisory ICSA-25-350-02 and Johnson Controls' security advisory page, but no CPE strings, model numbers, or firmware ranges were provided. Organizations should use those advisories to identify the affected Johnson Controls ICS devices and firmware and confirm whether any specific encrypted communication feature must be enabled.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The flaw is CWE-323 (Reusing a Nonce, Key Pair in Encryption) in Johnson Controls ICS encrypted communications. Nonces must be unique per encryption operation; reuse can allow attackers to recover keystream relationships, decrypt captured ciphertext, or replay previously observed packets. The CVSS v4 vector (AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:L) and assessed CVSS v3.1 vector (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L) agree that the attacker must be on the same local or adjacent network but needs no authentication or user interaction. No CPE data was provided, so exact models, firmware versions, and affected protocol modes cannot be enumerated from this input.

Know when Johnson Controls gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (jci) PRIMARY 7.2 HIGH
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:N
vuln.today AI 7.6 HIGH

Adjacent capture position gives AV:A with no auth or interaction (PR:N/UI:N); replay yields high integrity impact (I:H) while partial decryption gives only limited confidentiality (C:L).

3.1 AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L
4.0 AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:N

Primary rating from Vendor (jci).

CVSS VectorVendor: jci

Attack Vector
Adjacent
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
Low
Vulnerable system: Integrity
High
Vulnerable system: Availability
Low
Subsequent system: Confidentiality
Low
Subsequent system: Integrity
Low
Subsequent system: Availability
None

DescriptionCVE.org

Due to Nonce reuse, attackers can perform reply attack or decrypt captured packets.

Executive ViewAI

Why It Matters

Johnson Controls ICS encrypted communications contain a nonce-reuse flaw (CVE-2025-61739) that can let an attacker on an adjacent network replay captured traffic or decrypt intercepted data, with the greatest potential impact being integrity of control communications. Organizations operating these industrial control systems-particularly in critical facilities or OT environments-should treat this as a high-priority exposure because unauthorized manipulation or disclosure could undermine operational trust and safety. No public exploit identified at time of analysis, and no CISA KEV entry was noted; leadership should direct asset owners to confirm affected models and firmware against the Johnson Controls advisory and CISA ICSA-25-350-02.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include segmenting affected Johnson Controls ICS devices on isolated OT networks, restricting adjacent-network access, monitoring encrypted traffic for replay or anomalies, and following Johnson Controls and CISA ICSA-25-350-02 guidance.

Threat Intelligence Overview

EPSS Score
0.2%
Top 92% exploitable
Prevalence
Low
industry-specific Johnson Controls ICS/building-automation product, limited enterprise footprint
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Controlled
Automatable· derived
No
Human Impact
High

Priority Score

36
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +36
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

CVE-2026-71449 CRITICAL
9.3 Oct 01

Hard-coded cryptographic key in Johnson Controls EasyIO FS32 building automation controllers before firmware 3.0b63 perm

CVE-2026-64893 HIGH
7.3 Oct 01

Cleartext transmission of sensitive information in Johnson Controls EasyIO NEO (all versions before 3.3b25) lets an atta

CVE-2026-21653 HIGH
7.2 Jul 23

Server-Side Request Forgery in Johnson Controls CCure 9000 and the victor application server (versions 2.9 through 3.0)

CVE-2026-34496 HIGH
7.1 Jul 23

Privilege management weakness in Johnson Controls victor Web (video management client) on Windows lets a high-privileged

CVE-2026-34492 HIGH
7.0 Aug 14

External control of file name or path (CWE-73) in Johnson Controls Airwall before version 4.1 enables file manipulation

CVE-2026-64887 HIGH
7.0 Aug 14

Hard-coded cryptographic key exposure in Johnson Controls Airwall before version 4.1 enables local attackers to conduct

CVE-2026-27875 MEDIUM
6.9 Aug 21

Cleartext credential exposure in Johnson Controls Simplex Incident Manager / Autocall Fire Administrator (all versions b

CVE-2025-43876 HIGH
8.7 Dec 24

OS command injection in Johnson Controls devices can allow a low-privilege authenticated remote attacker to execute arbi

CVE-2025-43875 HIGH
8.7 Dec 24

Command injection in certain Johnson Controls devices allows a low-privilege authenticated attacker to execute arbitrary

CVE-2026-34499 HIGH
8.5 Oct 07

Hard-coded cryptographic key material embedded in Johnson Controls ADVMS builds prior to 3.10 lets a locally authenticat

CVE-2026-71456 HIGH
8.5 Oct 26

Use of a hard-coded cryptographic key in Johnson Controls Kantech EntraPass before 9.20 enables a padding oracle crypto

CVE-2026-64892 MEDIUM
6.3 Oct 01

Information disclosure in Johnson Controls Easy IO Neo versions before 3.3b63 allows an authenticated high-privileged at

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy