Johnson Controls ICS
CVE-2025-61739
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain adjacent-network foothold
-
DeliveryPassively capture encrypted packets
-
ExploitExploit reused nonce (CWE-323)
-
ExecutionReplay or decrypt traffic
-
ImpactDisclose data or forge/repeat messages
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A04:2025 - Cryptographic Failures
ASVS 5.0
V11 - Cryptography Nonce/key pair uniqueness
|
| Exploitation Conditions | Exploitation requires the attacker to occupy an adjacent/local network position (CVSS AV:A) relative to the affected Johnson Controls device so that encrypted traffic can be intercepted or injected - this cannot be performed remotely over the internet without such access. Given PR:N and UI:N, no authentication or victim interaction is needed once the attacker is on the network. The core flaw is cryptographic nonce reuse (CWE-323) in the product's encrypted communications, which permits replaying previously captured packets and/or decrypting captured ciphertext. The primary limiting factor is the adjacency requirement (same L2 segment/local network); the specific affected product, version, and whether any particular communication mode or feature must be in use are not specified in the provided data and should be confirmed against the Johnson Controls advisory and CISA ICSA-25-350-02. |
| Impact | This is a genuine but bounded risk, best characterized as a HIGH-severity (CVSS 4.0 base 7.2) cryptographic weakness whose real-world exploitability is constrained by network positioning rather than configuration. The CVSS vector reports adjacent-network access (AV:A), low complexity (AC:L), no privileges (PR:N) and no user interaction (UI:N), with impact weighted toward integrity (VI:H) over confidentiality (VC:L) and availability (VA:L) - consistent with CWE-323 (nonce reuse) enabling both replay (integrity) and limited packet decryption (confidentiality). Signals are coherent and point toward MODERATE priority: EPSS is low at 0.19% (8th percentile), there is no CISA KEV listing and no public exploit identified, so there is no evidence of active or widespread exploitation. No SSVC decision data was provided in the input. The AV:A requirement is the dominant limiting factor - an attacker must already be on the same local/adjacent network segment to capture traffic, which rules out remote internet-based mass exploitation and makes this most relevant to insider, lateral-movement, or physically-proximate threat models typical of ICS/building-automation environments. Net: prioritize patching for exposed or flat OT networks, but this is not an internet-facing drop-everything emergency given the adjacency constraint and low EPSS. |
| Exploit ScenarioDerived | An attacker with a foothold on the same local/adjacent network segment as the affected Johnson Controls device passively captures its encrypted traffic. Because the same nonce is reused during encryption (CWE-323), the attacker can replay captured packets to repeat prior commands/transactions or perform cryptanalysis to decrypt sensitive captured data. No public proof-of-concept exploit was identified in the provided intelligence, and exploitation requires adjacent-network access rather than remote reachability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 19, 2026
Nonce reuse in Johnson Controls ICS encrypted communications lets unauthenticated attackers on an adjacent network replay captured packets or decrypt intercepted traffic, with high integrity impact and limited confidentiality and availability impact. The supplied data does not name the exact affected device models or firmware versions, so scope must be confirmed against the Johnson Controls advisory and CISA ICSA-25-350-02. No public exploit code or CISA KEV entry was identified at time of analysis, and EPSS is 0.19%.
RemediationAI
No vendor-released patch or fixed firmware version is identified in the supplied data; check the Johnson Controls advisory (https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories) and CISA ICSA-25-350-02 (https://www.cisa.gov/news-events/ics-advisories/icsa-25-350-02) for the current fixed release and upgrade instructions. Because exploitation requires adjacency, isolate affected devices on dedicated VLANs or segments with strict ACLs and prevent untrusted hosts from sharing the same Layer 2 domain; the trade-off is added management complexity and possible disruption of legitimate local integrations. If the affected encrypted communication mode can be disabled or wrapped in a separately validated encrypted tunnel, do so after compatibility testing; the trade-off is loss of functionality or performance overhead. Monitor for replay or anomalous encrypted traffic and restrict physical and network access to the device segment.
Affected ProductsAI
Exact affected products and versions are not specified in the supplied data. The CVE is attributed to Johnson Controls and appears in CISA ICS advisory ICSA-25-350-02 and Johnson Controls' security advisory page, but no CPE strings, model numbers, or firmware ranges were provided. Organizations should use those advisories to identify the affected Johnson Controls ICS devices and firmware and confirm whether any specific encrypted communication feature must be enabled.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The flaw is CWE-323 (Reusing a Nonce, Key Pair in Encryption) in Johnson Controls ICS encrypted communications. Nonces must be unique per encryption operation; reuse can allow attackers to recover keystream relationships, decrypt captured ciphertext, or replay previously observed packets. The CVSS v4 vector (AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:L) and assessed CVSS v3.1 vector (AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L) agree that the attacker must be on the same local or adjacent network but needs no authentication or user interaction. No CPE data was provided, so exact models, firmware versions, and affected protocol modes cannot be enumerated from this input.
Know when Johnson Controls gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:N
Adjacent capture position gives AV:A with no auth or interaction (PR:N/UI:N); replay yields high integrity impact (I:H) while partial decryption gives only limited confidentiality (C:L).
Primary rating from Vendor (jci).
CVSS VectorVendor: jci
DescriptionCVE.org
Due to Nonce reuse, attackers can perform reply attack or decrypt captured packets.
Executive ViewAI
Johnson Controls ICS encrypted communications contain a nonce-reuse flaw (CVE-2025-61739) that can let an attacker on an adjacent network replay captured traffic or decrypt intercepted data, with the greatest potential impact being integrity of control communications. Organizations operating these industrial control systems-particularly in critical facilities or OT environments-should treat this as a high-priority exposure because unauthorized manipulation or disclosure could undermine operational trust and safety. No public exploit identified at time of analysis, and no CISA KEV entry was noted; leadership should direct asset owners to confirm affected models and firmware against the Johnson Controls advisory and CISA ICSA-25-350-02.
No vendor-released patch identified at time of analysis. Interim mitigations include segmenting affected Johnson Controls ICS devices on isolated OT networks, restricting adjacent-network access, monitoring encrypted traffic for replay or anomalies, and following Johnson Controls and CISA ICSA-25-350-02 guidance.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
More in Johnson Controls
View allHard-coded cryptographic key in Johnson Controls EasyIO FS32 building automation controllers before firmware 3.0b63 perm
Cleartext transmission of sensitive information in Johnson Controls EasyIO NEO (all versions before 3.3b25) lets an atta
Server-Side Request Forgery in Johnson Controls CCure 9000 and the victor application server (versions 2.9 through 3.0)
Privilege management weakness in Johnson Controls victor Web (video management client) on Windows lets a high-privileged
External control of file name or path (CWE-73) in Johnson Controls Airwall before version 4.1 enables file manipulation
Hard-coded cryptographic key exposure in Johnson Controls Airwall before version 4.1 enables local attackers to conduct
Cleartext credential exposure in Johnson Controls Simplex Incident Manager / Autocall Fire Administrator (all versions b
OS command injection in Johnson Controls devices can allow a low-privilege authenticated remote attacker to execute arbi
Command injection in certain Johnson Controls devices allows a low-privilege authenticated attacker to execute arbitrary
Hard-coded cryptographic key material embedded in Johnson Controls ADVMS builds prior to 3.10 lets a locally authenticat
Use of a hard-coded cryptographic key in Johnson Controls Kantech EntraPass before 9.20 enables a padding oracle crypto
Information disclosure in Johnson Controls Easy IO Neo versions before 3.3b63 allows an authenticated high-privileged at
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB