Skip to main content

PDF Architect CVE-2025-14417

HIGH
Product UI does not Warn User of Unsafe Actions (CWE-356)
2025-12-23 zdi-disclosures@trendmicro.com
7.8
CVSS 3.0 · Vendor: trendmicro
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Craft malicious PDF with Launch action
  2. Delivery
    Deliver via web page or email attachment
  3. Exploit
    Victim opens file in PDF Architect
  4. Execution
    Launch action runs script without warning
  5. Impact
    Code executes as current user

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V3 - Web Frontend Security Product UI inconsistency
Exploitation Conditions

Exploitation requires the victim to open an attacker-supplied file or visit a malicious page that is processed by PDF Architect, and specifically requires the PDF to contain a Launch action, which PDF Architect executes to run script without first displaying a user warning (the core defect). Limiting factors: mandatory user interaction (UI:R) - the attack cannot fire without the victim opening the content; the attack vector is local (AV:L), so there is no remote network-service exposure; and exploitation only affects installations of PDF Architect (CPE identifies version 9.1.74.23030). Code runs only in the context of the current user, so a low-privileged victim limits blast radius. No special server configuration is needed, but the user-interaction and local-file requirements significantly reduce the realistic attack surface compared with a network-exploitable flaw.

Impact

This is a file-format/client-side code execution flaw (CWE-356, Improper UI Layering/Insufficient UI Warning) in pdfforge PDF Architect, carrying a vendor/NVD CVSS 3.0 base score of 7.8 (CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The signals are mixed in an important way: the CVSS vector encodes AV:L (local attack vector), reflecting that exploitation requires the victim to open a malicious file or document locally, yet the description frames this as 'remote attackers' delivering a malicious page or file - this is the standard ZDI file-parsing pattern where delivery is remote but execution is local, so the AV:L is correct and the 'remote' wording refers to attacker origin, not network reachability. Low attack complexity (AC:L) and no privileges (PR:N) raise risk, but mandatory user interaction (UI:R) materially limits mass exploitation. No EPSS score, no CISA KEV listing, and no public POC were provided in the input, so there is no public exploit identified at time of analysis; combined with the consumer-grade, niche footprint of the product, this reads as a genuine high-severity bug but a lower real-world priority than a server-side or ubiquitous-product RCE. Patch and SSVC (automatable, exploitation status) data were not supplied - verify fixed version with pdfforge/ZDI before final triage.

Exploit ScenarioDerived

An attacker crafts a malicious PDF (or a web page that serves one) that abuses PDF Architect's Launch action to run a dangerous script without presenting any user warning. The victim opens the file in PDF Architect, and the embedded Launch action silently executes attacker-controlled code in the context of the current user. No public exploit code was identified in the provided data; the flaw was reported privately through Trend Micro's Zero Day Initiative (ZDI-CAN-27501 / ZDI-25-1074).

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 19, 2026

PDF Architect version 9.1.74.23030 executes embedded PDF Launch actions without first warning the user, so a crafted document can run arbitrary script in the victim's security context when opened. The flaw is local and requires user interaction, and no public exploit code has been identified at time of analysis; successful exploitation gives the attacker the same privileges as the current user.

RemediationAI

No vendor-released patch identified at time of analysis; monitor the ZDI advisory at https://www.zerodayinitiative.com/advisories/ZDI-25-1074/ for a vendor fix. In the interim, configure PDF Architect to require explicit confirmation before executing Launch actions or embedded scripts, if such a setting is available; this can break legitimate PDFs that intentionally launch external programs. Strip /Launch actions from untrusted PDFs using a sanitizer, email gateway, or download policy, and open suspicious documents in a sandboxed or low-privilege environment; these measures reduce exposure but add operational overhead and may interfere with document functionality. Enforce least privilege so that any successful exploitation is limited to the current user's rights.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The underlying issue is in PDF Architect's implementation of the PDF Launch action, a document feature that can invoke an external application or script. Instead of displaying a warning before execution, the application allows dangerous script to run, which is classified as CWE-356 (Insufficient UI Warning). The provided CPE identifies pdfforge PDF Architect 9.1.74.23030 as the affected build. Because exploitation requires the victim to open a crafted PDF or visit a malicious page that delivers one (UI:R), and the vector is local (AV:L), an attacker cannot trigger this against a remote service; code execution occurs only in the context of the current user.

Know when Pdf Architect gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (trendmicro) PRIMARY 7.8 HIGH
AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
vuln.today AI 7.8 HIGH

AV:L and UI:R because the victim must locally open a malicious file; PR:N as no authentication is needed; C/I/A:H since arbitrary code runs as the current user.

3.1 AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
4.0 AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (trendmicro).

CVSS VectorVendor: trendmicro

Attack Vector
Local
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

pdfforge PDF Architect Launch Insufficient UI Warning Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of pdfforge PDF Architect. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.

The specific flaw exists within the implementation of the Launch action. The issue results from allowing the execution of dangerous script without user warning. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-27501.

Executive ViewAI

Why It Matters

PDF Architect 9.1.74.23030 can execute embedded launch actions from a crafted PDF without warning the user, allowing code to run with that user’s privileges. No vendor-released patch is identified at time of analysis and no public exploit has been identified, but the flaw requires user interaction, so exposure is concentrated among staff who open PDFs from external sources. Leadership should care because a single malicious document could lead to unauthorized execution under a trusted account and put sensitive data or downstream systems at risk.

Business Impact: High
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include restricting PDF Architect 9.1.74.23030 to trusted documents, enforcing application allowlisting to block unexpected child processes from PDF Architect, filtering external PDFs at email and web gateways, disabling or blocking PDF Launch actions through endpoint policy where supported, and migrating to an alternative PDF reader until the vendor provides a fixed version.

Threat Intelligence Overview

EPSS Score
0.2%
Top 91% exploitable
Prevalence
Low
niche consumer/prosumer PDF editor, limited enterprise footprint
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact
High

Priority Score

39
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +39
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)CVE.org

cpe:2.3:a:pdfforge:pdf_architect:9.1.74.23030:*:*:*:*:*:*:*
CVE-2018-19150 HIGH POC
7.8 Nov 10

Memory corruption in PDMODELProvidePDModelHFT in pdmodel.dll in pdfforge PDF Architect 6 allows remote attackers to caus

CVE-2026-92176 HIGH
7.8 Sep 15

An out-of-bounds read in the App object handling of pdfforge's PDF Architect allows an attacker to execute arbitrary cod

CVE-2026-92177 HIGH
7.8 Sep 15

Opening a crafted PDF file in pdfforge PDF Architect can drive an out-of-bounds heap write inside the application's PDF

CVE-2026-92178 HIGH
7.8 Sep 15

Memory corruption in the PDF parsing routine of pdfforge PDF Architect lets an attacker execute arbitrary code in the co

CVE-2026-92179 HIGH
7.8 Sep 15

Remote attackers can achieve arbitrary code execution by luring a user into opening a maliciously crafted PDF document i

CVE-2026-92180 HIGH
7.8 Sep 15

Local privilege escalation in pdfforge PDF Architect allows an attacker who already holds low-privileged code execution

CVE-2025-14420 HIGH
7.8 Dec 23

Directory traversal in pdfforge PDF Architect 9.1.74.23030 allows unauthenticated attackers to execute arbitrary code by

CVE-2025-14419 HIGH
7.8 Dec 23

Memory corruption during PDF file parsing in pdfforge PDF Architect (confirmed affected build 9.1.74.23030) allows an at

CVE-2025-14418 HIGH
7.0 Dec 23

Code execution in pdfforge PDF Architect 9.1.74.23030 occurs when the application processes a crafted XLS file and runs

CVE-2025-14416 HIGH
7.0 Dec 23

Code execution in pdfforge PDF Architect 9.1.74.23030 occurs when a user opens a crafted DOC file, because the applicati

CVE-2025-14421 MEDIUM
5.5 Dec 23

An out-of-bounds read in pdfforge PDF Architect's PDF parsing routine (confirmed affected build 9.1.74.23030) allows an

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy