BLU-IC2/IC4 Firmware CVE-2025-12285
CRITICALAttack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach device management interface on network
-
ExploitAuthenticate with default initial credentials
-
ExecutionGain full administrative control
-
ImpactManipulate physical access / pivot to connected systems
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V2 - Validation and Business Logic Input validation, allowlisting
|
| Exploitation Conditions | Exploitation requires network reachability to the administrative/management interface of a BLU-IC2 or BLU-IC4 device running firmware 1.19.5 or earlier on which the initial/default password was never changed (the vulnerability is precisely that the device does not enforce this change at first setup). No valid user-supplied credentials, authentication, or user interaction are needed (PR:N/UI:N) - the known default credentials suffice. The main limiting factor is exposure: these are specialized intercom/access-control units typically deployed on internal or building networks, so risk is highest where the interface is reachable from untrusted networks or the internet, and is mitigated once an operator has manually set a strong non-default password. |
| Impact | The CVSS 4.0 base score of 10.0 (AV:N/AC:L/AT:N/PR:N/UI:N with high vulnerable- and subsequent-system impact VC/VI/VA:H and SC/SI/SA:H) reflects a trivially exploitable, unauthenticated flaw: the device does not force a change of its initial/default password, so anyone who can reach the management interface with known factory credentials gains full control. Weighing against the maximal CVSS, the EPSS probability is only 0.34% (26th percentile), and there is NO CISA KEV listing and NO public exploit referenced, so there is no evidence of active or widespread exploitation at this time. These signals are not strictly conflicting - default-credential issues score high on exploitability yet often show low EPSS because exploitation requires network reachability to the specific device and the affected product (Azure Access BLU-IC2/BLU-IC4 intercom/access controllers) is niche rather than internet-ubiquitous. No SSVC decision was supplied in the input, so automatable/technical-impact judgments are inferred from CVSS only. Net: a genuinely severe weakness where reachable, but likely targeted/opportunistic rather than mass-exploited given the specialized, typically internally-networked product; prioritize for any deployment whose management interface is network-accessible. |
| Exploit ScenarioDerived | An attacker with network access to a BLU-IC2 or BLU-IC4 unit (firmware ≤1.19.5) connects to its management interface and logs in using the unchanged factory/default credentials, because the device never required an initial password change. With full administrative access they can unlock doors, disable the access-control function, and pivot into connected building systems. No public exploit code is referenced, but no exploitation is needed beyond knowing the default credentials; the CVSS AV:N/AC:L/PR:N/UI:N vector confirms no authentication or user interaction is required. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 18, 2026
BLU-IC2 and BLU-IC4 access-control/intercom units running firmware 1.19.5 or earlier ship with a factory default password and never force the operator to replace it during initial provisioning, so anyone who can reach the management interface with the publicly known default credentials gains full administrative control of the device. The flaw is unauthenticated from the attacker's perspective (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C with high confidentiality, integrity and availability impact to both the device and connected systems) and carries a CVSS 4.0 base score of 10.0. Exploitation is not confirmed in the wild (not in CISA KEV) and no public exploit code has been identified at time of analysis, while EPSS sits at 0.34% (26th percentile) - real-world risk is driven almost entirely by whether the management interface of these specialized building-network devices is reachable from untrusted networks.
RemediationAI
No vendor-released patch with a confirmed fixed version is identified in the available data; consult https://azure-access.com/security-advisories to confirm whether firmware beyond 1.19.5 enforces a mandatory initial password change, and upgrade as soon as a fixed release is published. Until then, the single most effective action is to log in to every BLU-IC2 and BLU-IC4 device with the factory credentials and immediately set a strong, unique administrative password (and change any default service, ONVIF or SIP credentials), recording it in the organization's credential vault - this closes the vulnerability's precondition entirely, at the cost of a manual inventory-and-commissioning sweep across all sites. Complement that with network controls: place the devices on a dedicated management VLAN and restrict reachability to the web/admin interface via ACLs or firewall rules so only authorized administrative hosts can connect (trade-off: administrators lose convenient remote access and must use a jump host or VPN); block inbound access to the management port from the internet and disable WAN-side remote management where the product allows it (trade-off: remote-site maintenance requires VPN or on-site access). If the firmware supports it, enable HTTPS-only administration and centralized logging of authentication events, and alert on successful logins using default or shared credentials, since such logins are the primary detection signal for exploitation attempts. Organizations that cannot immediately rotate credentials should prioritize isolating internet-facing units first, as EPSS is low but the impact of a compromise of an access-control endpoint is full physical-security control.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected devices are embedded network appliances (CPE cpe:2.3:o:azure-access:blu-ic2_firmware and cpe:2.3:o:azure-access:blu-ic4_firmware) exposing an administrative/management service over the network; the vulnerability is that the firmware accepts factory default credentials indefinitely and provides no mandatory first-boot password rotation workflow. The assigned CWE-20 (Improper Input Validation) is a generic classification - the effective root cause is the absence of an enforced credential-change step at commissioning (closer to CWE-1392 Use of Default Credentials / CWE-1188 Initialization of a Resource with an Insecure Default), which is why the CVSS 4.0 vector shows AT:N and PR:N: no attack complexity, no authentication and no user interaction are required once the interface is reachable. Because the compromised component is a building access-control endpoint, the CVSS 4.0 subsequent-system metrics (SC:H/SI:H/SA:H) and the CVSS 3.1 scope-change rating reflect that an attacker who logs in can pivot beyond the device itself - reconfiguring intercom/door-control behavior, extracting configuration and possibly camera or credential data, and using the unit as a foothold on the internal network. The mitigating variable is exposure and operator hygiene: devices where a strong, unique administrative password was manually set at installation are effectively remediated, and units confined to segmented management VLANs present a much smaller attack surface.
Know when Blu Ic2 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Unenforced default password means no privileges needed (PR:N) over the network (AV:N/AC:L); full device control with scope change (S:C) since the access controller governs physical door/building systems.
Primary rating from Vendor (a0340c66-c385-4f8b-991b-3d05f6fd5220).
CVSS VectorVendor: a0340c66-c385-4f8b-991b-3d05f6fd5220
DescriptionCVE.org
Missing Initial Password Change.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.
Executive ViewAI
BLU-IC2 and BLU-IC4 access-control/intercom units running firmware 1.19.5 or earlier can be taken over by an unauthenticated attacker who reaches the management interface using factory default credentials, giving full administrative control over physical access and intercom functions. Leadership should care because a compromise could let an attacker change access permissions, disrupt building communications, or use the device as a foothold into connected building networks, especially where these interfaces are exposed beyond trusted networks. No public exploit identified at time of analysis, and no vendor-released patch identified at time of analysis; exposure reduction should focus on credential replacement and network access control.
No vendor-released patch identified at time of analysis. Interim mitigations: immediately change all factory default administrative credentials on BLU-IC2/BLU-IC4 firmware 1.19.5 or earlier; restrict management-interface access to trusted networks or VPN; segment devices from untrusted and general-purpose networks; disable remote management where not required; monitor authentication and configuration logs; and enforce unique strong passwords with periodic rotation.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
More in Blu Ic2 Firmware
View allUnauthenticated remote command execution affects Azure Access BLU-IC2 and BLU-IC4 firmware through version 1.19.5, where
Arbitrary file write via path traversal in the firmware upgrade feature of Azure Access BLU-IC2 and BLU-IC4 boards (firm
Outdated third-party UI dependencies in BLU-IC2 and BLU-IC4 firmware through 1.19.5 can expose the management web interf
Network-reachable BLU-IC2 and BLU-IC4 devices running firmware through 1.19.5 embed BusyBox 1.31.1 and are exposed to mu
Azure Access OS firmware through 1.19.5 on BLU-IC2 and BLU-IC4 physical access controllers contains unspecified vulnerab
Denial-of-service conditions in Azure Access Technology BLU-IC2 and BLU-IC4 firmware through 1.19.5 allow remote attacke
Unauthenticated remote attackers can retrieve server version information from Azure Access BLU-IC2 and BLU-IC4 physical
Unauthenticated remote access to a critical function in Azure Access BLU-IC2/IC4 firmware through 1.19.5 lets a network
Local privilege escalation in Azure Access BLU-IC2 and BLU-IC4 intercom firmware through 1.19.5 allows a lower-privilege
Weak password policy in Azure Access BLU-IC2 and BLU-IC4 intercom access controller firmware through version 1.19.5 can
BLU-IC2 and BLU-IC4 firmware through 1.19.5 contain undocumented administrative accounts that allow network-reachable at
Denial of service in Azure Access BLU-IC2 and BLU-IC4 firmware through 1.19.5 allows unauthenticated network attackers w
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB