Factorytalk View
CVE-2020-12031
HIGH
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.8 (HIGH). Attack characteristics: local attack vector, low complexity, low privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A local attacker with access to the system could corrupt memory to execute arbitrary code or crash the application. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 - Patch Roll-up for CPR9 SRx. Affected products include: Rockwellautomation Factorytalk View.
Know when Factorytalk View gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch 1126290. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 - Patch Roll-up for CPR9 SRx.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
Affected Products (CPE)NVD
More in Factorytalk View
View allIn all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to int
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. Rated high s
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. Rated med
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allo
CVE-2024-45824 IMPACT A remote code vulnerability exists in the affected products. Rated critical severity (CVSS 9.2), t
Unauthenticated attackers with network access to the same segment as a Rockwell Automation FactoryTalk View Machine Edit
A vulnerability exists in the Rockwell Automation FactoryTalk® View SE Datalog function that could allow a threat actor
CVE-2024-7513 IMPACT A code execution vulnerability exists in the affected product. Rated high severity (CVSS 8.5), this
A privilege escalation vulnerability exists in the affected product. Rated high severity (CVSS 8.5), this vulnerability
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. Rated high severity (CVSS 8.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. Rated high severity (CVS
Rockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow thr
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB