Factorytalk View
CVE-2024-37369
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V13 - Configuration Permission assignment review
|
| Impact | CVSS score of 8.5 (HIGH). Attack characteristics: local attack vector, low complexity, low privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A local attacker with access to the system could access resources due to misconfigured permissions. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A privilege escalation vulnerability exists in the affected product. Rated high severity (CVSS 8.5), this vulnerability is low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Review and restrict file/resource permissions, apply principle of least privilege.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Incorrect Permission Assignment (CWE-732), which allows attackers to access resources due to misconfigured permissions. A privilege escalation vulnerability exists in the affected product. The vulnerability allows low-privilege users to edit scripts, bypassing Access Control Lists, and potentially gaining further access within the system. Affected products include: Rockwellautomation Factorytalk View.
Know when Factorytalk View gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Primary rating from Vendor (rockwellautomation) · only source for this CVE.
CVSS VectorVendor: rockwellautomation
DescriptionCVE.org
A privilege escalation vulnerability exists in the affected product. The vulnerability allows low-privilege users to edit scripts, bypassing Access Control Lists, and potentially gaining further access within the system.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Privilege escalation occurs when an attacker leverages flaws in access control mechanisms to gain permissions beyond what they were originally granted.
Affected Products (CPE)CVE.org
More in Factorytalk View
View allIn all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to int
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. Rated high s
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. Rated med
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allo
CVE-2024-45824 IMPACT A remote code vulnerability exists in the affected products. Rated critical severity (CVSS 9.2), t
Unauthenticated attackers with network access to the same segment as a Rockwell Automation FactoryTalk View Machine Edit
A vulnerability exists in the Rockwell Automation FactoryTalk® View SE Datalog function that could allow a threat actor
CVE-2024-7513 IMPACT A code execution vulnerability exists in the affected product. Rated high severity (CVSS 8.5), this
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. Rated high severity (CVSS 8.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. Rated high severity (CVS
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a lo
Rockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow thr
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB