FactoryTalk View
CVE-2025-9064
HIGH
Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessGain access to adjacent OT network
-
DeliverySend crafted path-traversal request
-
ExploitReference known OS filename
-
ExecutionDelete critical panel file
-
ImpactDisrupt HMI availability
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A07:2025 - Authentication Failures
ASVS 5.0
V6 - Authentication Authentication mechanism validation
MITRE ATT&CK
2 techniques across 2 tactics: Defense Evasion, Initial Access The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Attacker must have network access to the same network segment as the FactoryTalk View Machine Edition panel (description states 'same network as the device,' suggesting adjacent/OT-network positioning despite the AV:N metric). No authentication is required (PR:N). The key limiting factor is that exploitation depends on prior knowledge of the exact filenames to be deleted - there is no implied directory enumeration, so blind deletion is not described. Impact is limited to file deletion (availability); no confidentiality or integrity compromise is indicated. Realistic risk is therefore bounded by OT network segmentation and the attacker's reconnaissance of valid filenames on the panel OS. |
| Impact | Signals are moderate and partly conflicting. The CVSS 4.0 base score of 8.7 (High) is driven entirely by availability impact (VA:H) with no confidentiality or integrity impact (VC:N/VI:N), reflecting that the flaw only permits arbitrary file deletion. The vector claims network reach (AV:N), low complexity (AC:L), and no privileges/interaction (PR:N/UI:N), which would normally justify urgency. However, the description explicitly scopes the attacker to 'the same network as the device,' implying adjacent/OT-segment access rather than true internet-facing exploitation - CVSS marks AV:N but the description implies adjacent network access, so verify reachability against your network segmentation. Exploitation is further gated by a real precondition: the attacker must know the exact filenames to delete, which lowers practical automatability. EPSS is low at 0.61% (47th percentile), there is no CISA KEV listing, and no public exploit was identified, so this is not evidence of active or widespread exploitation. Net: a legitimately high-impact availability bug in an ICS/OT product, but current threat-intel signals point to it being a patch-on-normal-cycle item rather than an emergency, especially where OT networks are properly segmented. |
| Exploit ScenarioDerived | An attacker with a foothold on the same OT/control network as a FactoryTalk View Machine Edition HMI panel sends a crafted request exploiting the path traversal to delete a known operating-system or application file on the panel, with no authentication required. By removing a critical runtime or configuration file, the attacker can crash or render the HMI inoperable, disrupting operator visibility and control. No public exploit code was identified at time of analysis, and the attacker must know specific target filenames. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 08, 2026
Unauthenticated attackers with network access to the same segment as a Rockwell Automation FactoryTalk View Machine Edition panel can exploit a path traversal flaw to delete arbitrary files within the panel's operating system, degrading availability of the HMI/operator station. The CVSS 4.0 score is 8.7 (AV:N/PR:N/UI:N/VA:H), but our independent assessment rates it 7.1 (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) because practical reachability is adjacent/OT-network rather than internet-wide, and exploitation hinges on the attacker already knowing exact filenames - no directory enumeration or integrity/confidentiality impact is described. There is no CISA KEV listing and no public exploit code identified at time of analysis; EPSS is low at 0.61% (47th percentile), so mass scanning is unlikely, but targeted OT intrusions remain a realistic vector.
RemediationAI
No exact fixed version is provided in the available data, so patch status cannot be independently confirmed - consult Rockwell Automation advisory SD1753 (https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html) and apply the vendor-recommended firmware update for FactoryTalk View Machine Edition as soon as it is published. Until a fix is applied, the primary control is network isolation: place panels on a dedicated OT VLAN and enforce ACLs/firewall rules so only required engineering workstations and controllers can reach them (trade-off: adds configuration overhead and can disrupt legitimate remote diagnostics). Restrict or disable unnecessary services and ports on the panel OS and use managed switches with port security or 802.1X to prevent rogue devices from joining the same segment (trade-off: requires network infrastructure support and may complicate ad-hoc maintenance). Because exploitation requires knowledge of exact filenames, tighten control over engineering documentation and backups that reveal panel file paths, and monitor panel file systems and event logs for unexpected deletions. Keep in mind these are compensating controls only; they reduce exposure but do not eliminate the flaw, and they should be validated against the panel's operational requirements before deployment in a live process environment.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
FactoryTalk View Machine Edition is Rockwell Automation's HMI runtime for panel-based operator terminals on the plant floor. The reported issue is a path traversal that allows file deletion on the underlying panel operating system without authentication, meaning the product's file-handling routine fails to properly neutralize directory traversal sequences in a filename/parameter it accepts. Notably, the supplied CWE-287 (Improper Authentication) does not match the described behavior; the tags ('Authentication Bypass', 'Path Traversal') and the description both point to a CWE-22/CWE-73-style improper path-name restriction, with authentication being effectively absent rather than flawed. The CPE cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:machine:*:*:* confirms the impact is scoped to the Machine Edition build across the identified version line, with no version constraint published. Because the attacker supplies a filename, the primitive behaves like an arbitrary-file-delete with a reconnaissance precondition, and the CVSS 4.0 vector records only high availability impact (VA:H) with no confidentiality or integrity effect, consistent with deletion-only behavior.
Know when Factorytalk View gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
Description limits the attacker to the same network, so AV:A not AV:N; unauthenticated (PR:N); file deletion yields availability-only impact (A:H, C:N/I:N).
Primary rating from Vendor (rockwellautomation).
CVSS VectorVendor: rockwellautomation
DescriptionCVE.org
A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.
Executive ViewAI
Rockwell Automation FactoryTalk View Machine Edition panels are affected by a high-severity path traversal vulnerability that allows unauthenticated attackers on the same network segment to delete arbitrary files, degrading HMI availability for operators. This could disrupt industrial processes and require manual intervention, impacting organizations relying on these panels for critical operations. With no vendor-released patch identified at time of analysis and no public exploit identified at time of analysis, the risk is currently low for mass exploitation but remains a realistic vector for targeted OT intrusions, so leadership should prioritize mitigation.
Apply network segmentation to isolate affected panels, restrict access to the OT segment, monitor for unauthorized file deletion, and maintain offline backups.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Authentication bypass attacks exploit flaws in the verification mechanisms that control access to systems and applications.
Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.
Affected Products (CPE)CVE.org
More in Factorytalk View
View allIn all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to int
All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. Rated high s
All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. Rated med
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allo
CVE-2024-45824 IMPACT A remote code vulnerability exists in the affected products. Rated critical severity (CVSS 9.2), t
A vulnerability exists in the Rockwell Automation FactoryTalk® View SE Datalog function that could allow a threat actor
CVE-2024-7513 IMPACT A code execution vulnerability exists in the affected product. Rated high severity (CVSS 8.5), this
A privilege escalation vulnerability exists in the affected product. Rated high severity (CVSS 8.5), this vulnerability
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. Rated high severity (CVSS 8.
A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. Rated high severity (CVS
In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a lo
Rockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow thr
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB