Bmc Firmware
CVE-2020-11488
MEDIUM
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A04:2025 - Cryptographic Failures
ASVS 5.0
V11 - Cryptography Signature verification
|
| Impact | CVSS score of 6.7 (MEDIUM). Attack characteristics: local attack vector, low complexity, high privileges required, no user interaction not required. |
| Exploit ScenarioDerived | Successful exploitation could compromise the medium-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which software. Rated medium severity (CVSS 6.7), this vulnerability is low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-347. NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which software does not validate the RSA 1024 public key used to verify the firmware signature, which may lead to information disclosure or code execution. Affected products include: Intel Bmc Firmware. Version information: prior to 3.38.30.
Know when Bmc Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior to 1.06.06, contains a vulnerability in the AMI BMC firmware in which software does not validate the RSA 1024 public key used to verify the firmware signature, which may lead to information disclosure or code execution.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
Affected Products (CPE)NVD
More in Bmc Firmware
View allNVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30, contain a vulnerability in the AMI BMC firmwa
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior
Privilege escalation in Intel Baseboard Management Controller (BMC) firmware before version 1.43.91f76955 may allow an u
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30, contains a Cross-Site Request Forgery (CSRF)
BMC Firmware in Intel server boards, compute modules, and systems potentially allow an attacker with administrative priv
NVIDIA DGX servers, all BMC firmware versions prior to 3.38.30, contain a vulnerability in the AMI BMC firmware in which
NVIDIA DGX servers, all BMC firmware versions prior to 3.38.30, contain a vulnerability in the AMI BMC firmware in which
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30 and all DGX-2 with BMC firmware versions prior
NVIDIA DGX servers, DGX-1 with BMC firmware versions prior to 3.38.30. Rated high severity (CVSS 7.5), this vulnerabilit
NVIDIA DGX servers, all DGX-1 with BMC firmware versions prior to 3.38.30, contains a vulnerability in the AMI BMC firmw
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB