Skip to main content

Ac18 Firmware CVE-2018-16333

HIGH
Buffer Overflow (CWE-119)
2018-09-02 cve@mitre.org
7.5
CVSS 3.0 · NVD
Share

Severity by source

NVD PRIMARY
7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

Lifecycle Timeline

1
CVE Published
Sep 02, 2018 - 03:29 nvd
HIGH 7.5

DescriptionNVD

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow.

AnalysisAI

An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. An issue was discovered on Tenda AC7 V15.03.06.44_CN, AC9 V15.03.05.19(6318)_CN, AC10 V15.03.06.23_CN, AC15 V15.03.05.19_CN, and AC18 V15.03.05.19(6318)_CN devices. There is a buffer overflow vulnerability in the router's web server. While processing the ssid parameter for a POST request, the value is directly used in a sprintf call to a local variable placed on the stack, which overrides the return address of the function, causing a buffer overflow. Affected products include: Tendacn Ac18 Firmware, Tendacn Ac15 Firmware, Tendacn Ac10 Firmware, Tendacn Ac9 Firmware, Tendacn Ac7 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.

CVE-2024-33182 CRITICAL POC
9.8 Jul 16

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet

CVE-2024-33180 CRITICAL POC
9.8 Jul 16

Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet

CVE-2024-33835 CRITICAL POC
9.8 May 01

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.

CVE-2024-28545 CRITICAL POC
9.8 Mar 26

Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload func

CVE-2024-2854 CRITICAL POC
9.8 Mar 24

A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Rated critical severity (CVSS 9.8), thi

CVE-2024-28537 CRITICAL POC
9.8 Mar 18

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function. Rated

CVE-2024-28553 CRITICAL POC
9.8 Mar 12

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Rated critic

CVE-2024-28535 CRITICAL POC
9.8 Mar 12

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Rat

CVE-2023-30135 CRITICAL POC
9.8 May 05

Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName paramet

CVE-2023-24166 CRITICAL POC
9.8 Jan 26

Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Rated critical severity (CVSS 9.8

CVE-2022-43260 CRITICAL POC
9.8 Oct 18

Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime fu

CVE-2022-40854 CRITICAL POC
9.8 Sep 23

Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Rated critical severity (CV

Share

CVE-2018-16333 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy