Data Center Expert EUVDEUVD-2026-75097

| CVE-2026-8044 HIGH
Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') (CWE-88)
2026-09-09 schneider GHSA-265c-qw8p-8m9f
8.6
CVSS 4.0 · Vendor: schneider
Share

Severity by source

Vendor (schneider) PRIMARY
8.6 HIGH
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
vuln.today AI
7.2 HIGH

Network-reachable backup function requires high-privilege auth; no scope change; full RCE yields C:H/I:H/A:H.

3.1 AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (schneider).

CVSS VectorVendor: schneider

Attack Vector
Network
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
X

Lifecycle Timeline

2
Analysis Generated
Sep 09, 2026 - 17:21 vuln.today
CVE Published
Sep 09, 2026 - 16:19 cve.org
HIGH 8.6

DescriptionCVE.org

CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') vulnerability exists that could cause remote code execution by an attacker with a privileged account when malicious arguments are provided as backup configuration parameters.

AnalysisAI

Remote code execution is possible in Schneider Electric EcoStruxure IT Data Center Expert (formerly StruxureWare Data Center Expert) versions 9.1.2 and prior via an argument injection flaw (CWE-88) in backup configuration parameter handling. An attacker holding a privileged account can supply crafted arguments that are passed unsanitized to an underlying backup command, resulting in arbitrary OS-level code execution on the server. …

Unlock full vulnerability intelligence

  • Risk assessment & exploitation conditions
  • Attack chain visualization
  • Remediation with exact patch versions
  • Threat intelligence from 22 sources
  • Personal watchlist & email alerts

Free forever · No credit card required

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata

Access
technique details hidden
Delivery
technique details hidden
Exploit
technique details hidden
Execution
technique details hidden
Persist
technique details hidden
Impact
technique details hidden

Vulnerability AssessmentAI

Exploitation Exploitation requires the attacker to authenticate to EcoStruxure IT Data Center Expert with a privileged (administrative) account - unauthenticated exploitation is not possible per the CVSS PR:H metric. … Additional conditions and limiting factors are described in the full assessment.
Risk Assessment The CVSS 4.0 score of 8.6 reflects a network-accessible, low-complexity attack requiring high-privilege authentication, with full confidentiality, integrity, and availability impact on the vulnerable system. … Full risk analysis with EPSS, KEV, and SSVC signal comparison available after sign-in.
Exploit Scenario Full exploit scenario with step-by-step reproduction available after sign-in.
Remediation Consult Schneider Electric security notice SEVD-2026-251-01 (available at the Schneider download portal linked in references) for the vendor-confirmed fixed version and upgrade instructions; the advisory should specify the minimum patched release beyond 9.1.2. … Detailed patch versions, workarounds, and compensating controls in full report.

Recommended ActionAI

Within 24 hours, create an inventory of all deployed EcoStruxure IT Data Center Expert instances running version 9.1.2 or prior and contact Schneider Electric to confirm patch timeline and availability. …

Sign in for detailed remediation steps and compensating controls.

Threat intelligence, references, and detailed analysis are available after sign-in.

Share

EUVD-2026-75097 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy