Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessAuthenticate with high privileges to PowerStore
-
DeliveryInject spreadsheet formula into a stored field
-
ExploitVictim exports or opens CSV report
-
ExecutionSpreadsheet auto-executes embedded formula
-
ImpactCode runs on victim's workstation
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V1 - Encoding and Sanitization CSV injection prevention
|
| Exploitation Conditions | Exploitation requires a high-privileged, authenticated account on the Dell PowerStore T-series management interface to inject a malicious spreadsheet formula (e.g., a cell beginning with =, +, -, or @) into a field that is subsequently rendered into a CSV export. The payload only executes when a second, separate user downloads that CSV and opens it in a spreadsheet application configured to evaluate formulas - so success depends on external software behavior (CSV sanitization/macro settings) that PowerStore does not control. Limiting factors: PR:H (attacker must already have elevated privileges), UI:R (a different victim user must open/export the file), and the impact is confined to that victim's workstation rather than the array. Affected PowerStore T-series and later models are fixed in version 5.1.0.0-2798105. |
| Impact | This is a low-to-moderate priority issue, not an urgent one, and the signals are internally consistent rather than conflicting. The CVSS 3.1 base score is 4.8 (Medium), and the vector CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N shows two strong brakes: PR:H means the attacker must already hold high privileges on the PowerStore management interface, and UI:R means a separate victim user must open or export the resulting CSV for the payload to fire. The S:C (scope change) and network attack vector are what keep it off the floor, because the eventual code execution lands on a different system - another operator's workstation - rather than on the array itself; impact is only Low to confidentiality and integrity with no availability effect. There is no EPSS score, no CISA KEV listing, and no public exploit or PoC reference in the supplied data, so exploitation is neither confirmed nor demonstrated. The vendor's own priority label is 'this_month', which aligns with a patch-in-routine-cycle posture rather than emergency action. The main caveat is that CSV/formula-injection outcomes depend heavily on the victim's spreadsheet software and its macro/formula settings, which are outside the array's control and not described in the available sources. |
| Exploit ScenarioDerived | A high-privileged PowerStore administrator (or an attacker who has already compromised such an account) seeds a malicious spreadsheet formula into a field that is later included in an exported CSV report. When a second operator downloads that report and opens it in a spreadsheet application that auto-executes formulas, the payload runs in the context of that victim's workstation. No public exploit code or PoC is identified in the available data, and the network attack vector with low complexity is offset by the need for high privileges and victim interaction. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Nov 18, 2026
CSV injection (CWE-1236) in Dell PowerStore T-series storage management software allows a high-privileged, authenticated user to write spreadsheet formula payloads into fields that are later rendered into CSV exports, so that a second, different user who downloads and opens the file in a formula-evaluating spreadsheet application may execute attacker-supplied content on their own workstation. The flaw is rated CVSS 4.8 (AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N), reflecting that the attacker must already hold elevated privileges, that a separate victim must open the export, and that impact is confined to the victim's endpoint rather than the array itself. No public exploit code has been identified at time of analysis and the issue is not flagged as actively exploited; Dell has released a fixed build and the vendor advisory is the authoritative source. Overall this is a low-to-moderate priority item with internally consistent signals rather than an urgent one.
RemediationAI
Vendor-released patch: upgrade PowerStore management software to version 5.1.0.0-2798105 or later, which is the fixed build listed for every affected model (500T through 9500) in the EUVD version data and in Dell advisory DSA-2026-479 (https://www.dell.com/support/kbdoc/en-us/000527640/dsa-2026-479-dell-powerstore-t-security-update-for-multiple-vulnerabilities). Because the advisory bundles multiple PowerStore vulnerabilities, confirm the target build matches 5.1.0.0-2798105 exactly rather than assuming an earlier 5.1.x update resolves this CVE. The sources describe no alternative workaround or compensating control; updating is the fix Dell provides. Note that residual exposure after patching depends on the receiving endpoint, since the payload only acts when an exported CSV is opened by a spreadsheet application configured to evaluate formulas - behavior the array does not control. Given the this_month priority label, schedule the upgrade within the current patch cycle rather than as an emergency change.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The root cause class is CWE-1236, Improper Neutralization of Formula Elements in a CSV File - commonly called CSV injection or formula injection. Storage management consoles routinely offer report and inventory exports as CSV; if user-controlled text fields (names, descriptions, alerts, or similar metadata) are written into the export without escaping leading formula characters such as =, +, -, or @, a spreadsheet application that opens the file may treat the cell as a formula rather than literal text and evaluate it. The CPE inventory covers the PowerStore T-series and Q-series appliance models - PowerStore 500T, 1000T, 1200T, 3000T, 3200Q, 3200T, 5000T, 5200Q, 5200T and 7000T in the CPE list, with the tag set and EUVD version records extending coverage to the 9000T, 9200T, 1500, 5500 and 9500 models. The vulnerability lives in the management software layer, not in the storage data path. The exact input field and code path that produce the unsanitized CSV cell are not described in the available sources. Exploitation is conditional on external software behavior - whether the receiving spreadsheet application has formula or macro evaluation enabled and whether it sanitizes imported cells - which PowerStore does not control.
Know when Powerstore 500T gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
High-privileged injection (PR:H) over the network interface with low complexity, requiring a separate victim to open the export (UI:R); code runs on that other workstation, hence scope change (S:C) with Low C/I and no availability impact.
Primary rating from Vendor (dell).
CVSS VectorVendor: dell
Lifecycle Timeline
1DescriptionCVE.org
Dell PowerStore contains a CSV Injection vulnerability. A high-privileged attacker could exploit this vulnerability, potentially leading to code execution on another user's workstation.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
More in Powerstore 500T
View allDell PowerStore SDNAS on affected PowerStore NAS nodes is vulnerable to unauthenticated OS command injection that can le
OS command injection in Dell PowerStore T-series SDNAS allows attackers with internal network reachability to execute ar
Unauthenticated remote code execution or denial of service against Dell PowerStore T-series NAS nodes is possible via a
Dell PowerStore storage appliances running the SDNAS NAS service contain an unauthenticated remote stack-based buffer ov
Remote code execution and denial of service in Dell PowerStore T-series arrays (SDNAS software) stem from an out-of-boun
Unauthenticated information disclosure in Dell PowerStore T-series storage appliances allows an attacker with network ac
Out-of-bounds write in the Dell PowerStore storage-processor interconnect driver lets a malicious peer on the array's in
OS command injection in Dell PowerStore T- and Q-series storage appliances allows an attacker who already holds high-pri
OS command injection in Dell PowerStore storage appliances allows an authenticated management-plane user to execute oper
OS command injection in Dell PowerStore storage appliances enables a locally authenticated user with limited privileges
Command injection in Dell PowerStore storage appliances allows an authenticated low-privileged local user to execute arb
An authorization bypass in Dell PowerStore storage appliances lets a user who already holds valid low-privileged credent
EUVD-2026-128831
GHSA-87g8-3jcj-wcg4
NVD
CVE.org
EPSS
Vulnrichment
Exploit-DB