Skip to main content
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Gain internal network access to NAS node
  2. Delivery
    Send crafted input to SDNAS interface
  3. Exploit
    Inject OS command via unsanitized parameter
  4. Execution
    Execute arbitrary commands as root
  5. Impact
    Full control of NAS node and stored data

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization OS command sanitization, avoid shell exec
MITRE ATT&CK

2 techniques across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires network reachability to the SDNAS service on a Dell PowerStore T-series NAS node; Dell scopes this to 'internal network access' rather than direct internet exposure, so attacker position on the storage/management network (or a prior foothold) is the primary prerequisite. Per the CVSS vector no authentication (PR:N) and no user interaction (UI:N) are needed, and attack complexity is low (AC:L), meaning no special non-default configuration is indicated as required by the available description. The main limiting factor is the 'internal network access' constraint: in segmented deployments where the PowerStore management/NAS network is isolated from untrusted users, reachable attack surface is substantially reduced. The specific vulnerable SDNAS feature or parameter that accepts the injected command is not described in the available sources.

Impact

This is a genuine high-priority issue, not a high-CVSS-but-low-real-risk artifact. The supplied CVSS 3.1 vector (AV:N/AC:L/PR:N/UI:N) rates it 9.8 Critical, and PR:N indicates no authentication is required, while root-level OS command injection (CWE-78) yields full confidentiality, integrity and availability impact on the NAS node. The vuln.today decision label is act_now, which signals urgency and should drive prioritization. One important nuance: the CVSS vector encodes AV:N (network), but Dell's description scopes the attacker to 'internal network access' - so realistic exposure depends on whether the PowerStore management/data network is segmented from untrusted zones, which tempers the raw 9.8 in well-segmented environments but not in flat networks. No EPSS score was provided, the CVE is not listed in CISA KEV, and no public exploit or PoC reference is present in the input, so there is no public exploit identified at time of analysis; the priority here rests on severity plus the act_now decision label rather than on observed exploitation or a known PoC.

Exploit ScenarioDerived

An attacker positioned on the internal/management network of a Dell PowerStore T-series array sends crafted input to the SDNAS component, which fails to sanitize it before passing it to an OS shell, injecting attacker-controlled commands. Per the CVSS vector no authentication is required (PR:N) and complexity is low (AC:L), so a single crafted request yields arbitrary command execution as root on the NAS node. No public exploit was identified at time of analysis, so weaponization effort is unknown.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 2.1% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Nov 18, 2026

Dell PowerStore SDNAS on affected PowerStore NAS nodes is vulnerable to unauthenticated OS command injection that can let an attacker with internal network reachability execute arbitrary commands as root on the NAS node. The assessed vector indicates low attack complexity, no authentication or user interaction, and high confidentiality, integrity and availability impact; the exact vulnerable SDNAS feature is not described in the available sources. No public exploit identified at time of analysis.

RemediationAI

Apply the PowerStoreOS security update directed by Dell advisory DSA-2026-479 at https://www.dell.com/support/kbdoc/en-us/000527640/dsa-2026-479-dell-powerstore-t-security-update-for-multiple-vulnerabilities; the supplied data does not include an exact fixed version, so obtain the applicable fixed release from the advisory. Until the update is applied, restrict network reachability to the SDNAS service on PowerStore NAS nodes to trusted internal storage and management networks, consistent with Dell's stated 'internal network access' prerequisite; no other workarounds are specified in the supplied sources.

Affected VersionsENISA

PowerStore 9000T 0 <5.1.0.0-2798105 or later
PowerStore 3200T 0 <5.1.0.0-2798105 or later
PowerStore 500T 0 <5.1.0.0-2798105 or later
PowerStore 5500 0 <5.1.0.0-2798105 or later
PowerStore 3200Q 0 <5.1.0.0-2798105 or later
PowerStore 5200Q 0 <5.1.0.0-2798105 or later
PowerStore 5000T 0 <5.1.0.0-2798105 or later
PowerStore 3000T 0 <5.1.0.0-2798105 or later
PowerStore 1500 0 <5.1.0.0-2798105 or later
PowerStore 9200T 0 <5.1.0.0-2798105 or later
PowerStore 5200T 0 <5.1.0.0-2798105 or later
PowerStore 9500 0 <5.1.0.0-2798105 or later
PowerStore 1200T 0 <5.1.0.0-2798105 or later
PowerStore 1000T 0 <5.1.0.0-2798105 or later
PowerStore 7000T 0 <5.1.0.0-2798105 or later

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The issue is CWE-78 (Improper Neutralization of Special Elements used in an OS Command), meaning user-influenced input can reach an operating-system command invocation without adequate neutralization. The affected component is SDNAS on Dell PowerStore NAS nodes; the supplied CPE entries list PowerStore 500T, 1000T, 1200T, 3000T, 3200Q, 3200T, 5000T, 5200Q, 5200T and 7000T with wildcard versions, so exact PowerStoreOS builds are not pinned by the available data. The specific SDNAS feature or parameter that accepts the injected command is not described in the available sources. Per the assessed CVSS vector, exploitation is network-reachable, low complexity, requires no authentication and no user interaction, and can yield high confidentiality, integrity and availability impact; Dell scopes the attacker prerequisite to internal network access.

Know when Powerstore 500T gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (dell) PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
vuln.today AI 9.8 CRITICAL

Network-reachable SDNAS service, no authentication or interaction stated, low-complexity command injection giving root execution, so full C/I/A impact with unchanged scope.

3.1 AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Primary rating from Vendor (dell).

CVSS VectorVendor: dell

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
Patch available
Nov 18, 2026 - 17:03 EUVD
CVE Published
Nov 18, 2026 - 15:44 cve.org
CRITICAL 9.8

DescriptionCVE.org

Dell PowerStore SDNAS contains an OS Command Injection vulnerability that could allow an attacker with internal network access to execute arbitrary commands as root on the NAS node.

Executive ViewAI

Why It Matters

Dell PowerStore NAS nodes are exposed to a critical unauthenticated command injection vulnerability that could allow an attacker with internal network access to execute commands as root, compromising the confidentiality, integrity, and availability of stored data and NAS services. Leadership should prioritize immediate mitigation because this flaw affects core storage infrastructure and could lead to data breaches, ransomware deployment, or prolonged service outages.

Business Impact: Severe
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations: restrict internal network access to PowerStore NAS nodes via firewall and network segmentation to only trusted sources; enforce strict access controls and monitoring; disable unnecessary services; and conduct regular security assessments to detect exploitation attempts.

Threat Intelligence Overview

EPSS Score
2.1%
Top 18% exploitable
Prevalence
Medium
enterprise Dell storage appliance, common in data centers but not ubiquitous
Data Quality
5 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 2.1%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision
Out-of-Cycle
Exploitation
None
System Exposure· derived
Open
Automatable
Yes
Human Impact
Very High
Technical Impact
Total

Priority Score

51
Low Medium High Critical
KEV: 0
EPSS: +2
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

OS command injection occurs when an application passes unsanitized user input directly into system shell commands.

CVE-2026-116448 CRITICAL
9.8 Nov 18

OS command injection in Dell PowerStore T-series SDNAS allows attackers with internal network reachability to execute ar

CVE-2026-116440 CRITICAL
9.8 Nov 19

Unauthenticated remote code execution or denial of service against Dell PowerStore T-series NAS nodes is possible via a

CVE-2026-116443 CRITICAL
9.8 Nov 18

Dell PowerStore storage appliances running the SDNAS NAS service contain an unauthenticated remote stack-based buffer ov

CVE-2026-67271 CRITICAL
9.8 Aug 18

Remote code execution and denial of service in Dell PowerStore T-series arrays (SDNAS software) stem from an out-of-boun

CVE-2026-58574 CRITICAL
9.8 Aug 31

Unauthenticated information disclosure in Dell PowerStore T-series storage appliances allows an attacker with network ac

CVE-2026-116441 CRITICAL
9.6 Nov 18

Out-of-bounds write in the Dell PowerStore storage-processor interconnect driver lets a malicious peer on the array's in

CVE-2026-111508 CRITICAL
9.1 Nov 18

OS command injection in Dell PowerStore T- and Q-series storage appliances allows an attacker who already holds high-pri

CVE-2026-103813 CRITICAL
9.1 Nov 13

OS command injection in Dell PowerStore storage appliances allows an authenticated management-plane user to execute oper

CVE-2026-58571 HIGH
8.8 Sep 01

OS command injection in Dell PowerStore storage appliances enables a locally authenticated user with limited privileges

CVE-2026-79682 HIGH
8.8 Sep 01

Command injection in Dell PowerStore storage appliances allows an authenticated low-privileged local user to execute arb

CVE-2026-82156 HIGH
8.8 Nov 16

An authorization bypass in Dell PowerStore storage appliances lets a user who already holds valid low-privileged credent

CVE-2026-79684 HIGH
8.8 Sep 01

Privilege escalation in Dell PowerStore storage appliances allows any authenticated low-privilege user to bypass access