Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
7DescriptionCVE.org
A vulnerability has been found in Tenda F456 1.0.0.5. This issue affects the function fromNatStaticSetting of the file /goform/NatStaticSetting. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
AnalysisAI
Stack-based buffer overflow in Tenda F456 router firmware v1.0.0.5 allows authenticated remote attackers to achieve code execution with high integrity and availability impact via crafted 'page' parameter to the /goform/NatStaticSetting endpoint's fromNatStaticSetting function. Public exploit code exists (EPSS 0.05%, 14th percentile), indicating low observed exploitation probability despite proof-of-concept availability. No active exploitation confirmed via CISA KEV at time of analysis.
Technical ContextAI
This vulnerability affects the NAT static port mapping configuration interface in Tenda F456 wireless routers running firmware version 1.0.0.5. The fromNatStaticSetting function in the /goform/NatStaticSetting handler fails to properly validate the length of the 'page' parameter before copying it to a fixed-size stack buffer, resulting in CWE-121 (stack-based buffer overflow). Stack overflows in embedded device web interfaces are particularly dangerous as they typically run with root/administrative privileges and can overwrite return addresses to redirect execution flow. The CPE identifier cpe:2.3:a:tenda:f456:*:*:*:*:*:*:*:* confirms this affects the application layer of the F456 router product line. CVSS 4.0 metrics indicate network-accessible attack vector with low complexity, requiring only low-privilege authenticated access to the web management interface.
RemediationAI
No vendor-released patch identified at time of analysis; Tenda has not published a security advisory or firmware update addressing CVE-2026-6198 for the F456 model. Organizations should immediately implement compensating controls: restrict management interface access to trusted internal networks only by disabling WAN-side administration, implement strong non-default administrative credentials, and deploy network segmentation to isolate affected routers from critical assets. Monitor Tenda's official support portal at https://www.tenda.com.cn/ for future firmware releases addressing this vulnerability. For high-security environments, consider replacing affected devices with alternative router models from vendors with established security patch programs. If administrative access from untrusted networks is absolutely required, deploy VPN access rather than exposing the web interface directly. Refer to VulDB advisory https://vuldb.com/vuln/357120 and NVD entry https://nvd.nist.gov/vuln/detail/CVE-2026-6198 for ongoing updates.
Tenda ONT GPON AC1200 Dual band WiFi HG9 v1.0.1 is vulnerable to Command Injection via the Ping function. Rated high sev
Mediabridge Medialink MWN-WAPR300N devices with firmware 5.07.50 and Tenda N3 Wireless N150 devices allow remote attacke
The Shenzhen Tenda Technology Tenda A5s router with firmware 3.02.05_CN allows remote attackers to bypass authentication
Tenda AC9 v15.03.05.14 was discovered to contain a command injection vulnerability via the Telnet function. Rated critic
In Tenda AC9 v1.0 V15.03.05.14_multi, the wanMTU parameter of /goform/AdvSetMacMtuWan has a stack overflow vulnerability
Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formSetSambaConf function via
Tenda AC9 V15.03.06.42_multi was found to contain a command injection vulnerability in the formsetUsbUnload function via
Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Rated critical severity (CV
Tenda AC15 v15.03.05.19 is vulnerable to Command Injection via the handler function in /goform/telnet. Rated critical se
Tenda AX1803 v1.0.0.1 was discovered to contain a command injection vulnerability via the function fromAdvSetLanIp. Rate
Tenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /
In the Tenda ac9 v1.0 router with firmware V15.03.05.14_multi, there is a stack overflow vulnerability in /goform/WifiWp
Same weakness CWE-121 – Stack-based Buffer Overflow
View allSame technique Stack Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-22058
GHSA-xr22-3p6x-xw4f