Severity by source
CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Local vector and TOCTOU timing requirement justify AV:L and AC:H; low-privilege local account needed to write to staging path drives PR:L; high integrity and availability reflect full file-replacement impact.
Primary rating from Vendor (Honeywell).
CVSS VectorVendor: Honeywell
Lifecycle Timeline
1DescriptionCVE.org
Honeywell IQ MultiAccess, all versions prior to and including version 28, contain an improper digital signature verification vulnerability. An attacker could potentially exploit this vulnerability, leading to the replacement of downloaded file with a malicious one. Honeywell also recommends updating to the most recent version of this product, service, or offering [V27 SP1, V28 SP1]
AnalysisAI
Honeywell IQ MultiAccess physical access control software, all versions through V28, improperly verifies digital signatures on downloaded files due to a time-of-check/time-of-use (TOCTOU) race condition, allowing a local low-privileged attacker to replace a legitimately verified file with a malicious one in the window between signature check and file consumption. Successful exploitation yields high integrity and availability impact on the vulnerable system, as the replaced file may execute attacker-controlled code or corrupt system components. No public exploit identified at time of analysis; Honeywell has released patches V27 SP1 and V28 SP1.
Technical ContextAI
The root cause is CWE-367 (Time-of-Check Time-of-Use Race Condition): the software checks a downloaded file's digital signature and then - in a separate, non-atomic step - uses or installs that file. An attacker with local file-system write access to the staging path can race the process, substituting the legitimate file with a malicious payload after the signature passes validation but before the file is consumed. The affected product (CPE: cpe:2.3:a:honeywell_technologies:iq_multiaccess:*:*:*:*:*:*:*:*) is Honeywell's IQ MultiAccess, an enterprise physical access control management platform. The CVSS 4.0 vector encodes the attack prerequisites as AT:P, reflecting the non-trivial timing requirement inherent to TOCTOU exploitation.
RemediationAI
Upgrade to V27 SP1 or V28 SP1, as confirmed by Honeywell in their product security advisory at https://www.honeywell.com/us/en/product-security. These are the only versions that remediate the improper signature verification logic. As a compensating control pending patch deployment, restrict local interactive and network-share access to the IQ MultiAccess host so that only trusted administrators can write to file-staging directories used during software download operations; this reduces the attacker's ability to perform the file-swap in the race window, though it does not eliminate the underlying flaw. Enforcing least-privilege principles - removing unnecessary local user accounts and auditing write permissions on update staging paths - also limits exploitation opportunity.
An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R
Directory traversal vulnerability in the FTP server on Honeywell Excel Web XL1000C50 52 I/O, XL1000C100 104 I/O, XL1000C
Improper Input Validation vulnerability in Honeywell PM43 on 32 bit, ARM (Printer web page modules) allows Command Injec
Honeywell NVR devices allow remote attackers to create a user account in the admin group by leveraging access to a guest
Honeywell Intermec PM23, PM42, PM43, PC23, PC43, PD43, and PC42 industrial printers before 10.11.013310 and 10.12.x befo
Multiple stack-based buffer overflows in (1) HWOPOSScale.ocx and (2) HWOPOSSCANNER.ocx in Honeywell OPOS Suite before 1.
A cross-site scripting (XSS) vulnerability in the component /test/ of iq3xcite v2.31 to v3.05 allows attackers to execut
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Honeywell MB
Unauthenticated access to Honeywell IQ4x building controller HMI. CVSS 10.0.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-
Controller may be loaded with malicious firmware which could enable remote code execution. Rated critical severity (CVSS
Same technique Information Disclosure
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-40126
GHSA-93h9-2372-g58v