Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Network-reachable management UI with low complexity, but requires an authenticated privileged admin (PR:H); memory-corruption code execution yields full C/I/A impact on the appliance with no scope change.
Primary rating from Vendor (WatchGuard).
CVSS VectorVendor: WatchGuard
Lifecycle Timeline
1DescriptionCVE.org
An Out-of-bounds Write vulnerability in WatchGuard Fireware OS wgagent process could allow an authenticated privileged user to execute arbitrary code via a specially crafted requests to the Management Web UI.This vulnerability affects Fireware OS 12.1 up to and including 12.12 and 2025.1 up to and including 2026.2.
AnalysisAI
Authenticated arbitrary code execution in WatchGuard Fireware OS (12.1-12.12 and 2025.1-2026.2) arises from an out-of-bounds write in the wgagent process, reachable when a privileged user sends specially crafted requests to the Management Web UI. A high-privilege attacker (or one who has compromised admin credentials) can corrupt memory to run code on the firewall appliance, undermining the security gateway itself. No public exploit has been identified at time of analysis, and the issue is not listed in CISA KEV.
Technical ContextAI
Fireware OS is the firmware powering WatchGuard Firebox network security appliances, and wgagent is a backend process that services requests originating from the appliance's Management Web UI. The flaw is a CWE-787 Out-of-bounds Write (memory corruption): input from a crafted management request is written past the bounds of an allocated buffer, corrupting adjacent memory. On network appliances such conditions are frequently exploitable for control-flow hijack and code execution because the affected process typically runs with elevated privileges. The single CPE provided (cpe:2.3:a:watchguard:fireware_os) confirms the affected component is the Fireware OS application layer rather than a third-party library.
RemediationAI
Upgrade Fireware OS to the fixed release identified in WatchGuard PSIRT advisory WGSA-2026-00021 (https://www.watchguard.com/wgrd-psirt/advisory/wgsa-2026-00021); the input does not include a specific fixed version number, so treat patch status as available per vendor advisory and confirm the exact patched build for your branch (12.x versus 2025.1/2026.x) directly from that advisory before deploying. As compensating controls until patched, restrict access to the Management Web UI to a dedicated management network or trusted admin IP allowlist and disable management access on external/WAN interfaces (trade-off: remote administrators must use VPN or on-network access), enforce strong and unique administrator credentials with MFA to reduce the chance an attacker satisfies the PR:H requirement, and monitor management-interface logs for anomalous or malformed requests. Because exploitation requires an authenticated privileged account, tightening who holds Firebox admin credentials and rotating them materially reduces exposure.
More in Watchguard
View allWatchGuard Fireware OS contains an out-of-bounds write in IKEv2 VPN handling enabling unauthenticated remote code execut
Watchguard XCS 9.2 and 10.0 before build 150522 allow remote authenticated users to execute arbitrary commands via shell
Remote code execution in WatchGuard Fireware OS arises from an out-of-bounds write in the iked (IKE) daemon, letting an
SQL injection vulnerability in Watchguard XCS 9.2 and 10.0 before build 150522 allows remote attackers to execute arbitr
On WatchGuard Firebox and XTM appliances, an unauthenticated user can execute arbitrary code, aka FBX-22786. Rated criti
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Rated critical seve
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15, and AP300 devices w
WatchGuard RapidStream appliances allow local users to gain privileges and execute arbitrary commands via a crafted ifco
An issue was discovered on WatchGuard AP100, AP102, and AP200 devices with firmware before 1.2.9.15. Rated high severity
An FBX-5312 issue was discovered in WatchGuard Fireware before 12.0. Rated high severity (CVSS 7.5), this vulnerability
WatchGuard Fireware v11.12.1 and earlier mishandles requests referring to an XML External Entity (XXE), in the XML-RPC a
WatchGuard Firebox and XTM appliances allow an unauthenticated remote attacker to retrieve sensitive authentication serv
Same weakness CWE-787 – Out-of-bounds Write
View allSame technique Memory Corruption
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2026-41454