Skip to main content

Tanium Connect CVE-2026-12139

| EUVDEUVD-2026-46406 MEDIUM
Invocation of Process Using Visible Sensitive Information (CWE-214)
2026-07-21 Tanium GHSA-w2w5-6rpf-f2w8
5.5
CVSS 3.1 · NVD
Share

Severity by source

Vendor (Tanium) PRIMARY
MEDIUM
qualitative
NVD
5.5 MEDIUM
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
vuln.today AI
4.4 MEDIUM

Local-only vector confirmed by CWE-214 process-invocation class; PR:H because inspection of process state requires existing elevated administrative access.

3.1 AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N
4.0 AV:L/AC:L/AT:N/PR:H/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N

Primary rating from Vendor (Tanium).

CVSS VectorNVD

Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
None
Availability
None

Lifecycle Timeline

3
CVSS changed
Aug 18, 2026 - 19:07 NVD
4.4 (MEDIUM) 5.5 (MEDIUM)
Patch available
Jul 21, 2026 - 23:36 EUVD
Analysis Generated
Jul 21, 2026 - 21:13 vuln.today

DescriptionNVD

Tanium addressed an information disclosure vulnerability in Connect.

AnalysisAI

Information disclosure in Tanium Connect exposes sensitive data to local administrators via process invocation metadata. The vulnerability (CWE-214) allows a locally authenticated, highly privileged user to observe sensitive information - such as credentials or tokens - that the Connect component surfaces through visible process arguments or environment state. No active exploitation has been identified and no public proof-of-concept exists, but the high confidentiality impact (C:H) means exposed data could facilitate lateral movement or privilege escalation within the Tanium management plane.

Technical ContextAI

CWE-214 (Invocation of Process Using Visible Sensitive Information) describes a class of vulnerabilities where a process exposes sensitive data - credentials, API keys, tokens - through mechanism such as command-line arguments, environment variables, or inter-process communication that are visible to other privileged users on the same host. Tanium Connect is a data integration component of the Tanium endpoint management platform, used to relay telemetry and connect Tanium with external systems such as SIEMs or databases. The affected CPE (cpe:2.3:a:tanium:connect:*:*:*:*:*:*:*:*) covers all versions of the Connect application without a constrained version range in the available data. The local attack vector (AV:L) and high privilege requirement (PR:H) confirm that exploitation is confined to users who already hold administrative or operator-level access on the host running Connect.

RemediationAI

Consult and apply the vendor-issued fix documented in Tanium advisory TAN-2026-018 at https://security.tanium.com/TAN-2026-018 - an exact patched version is not independently confirmed from the available data, so reference the advisory directly for the target upgrade version. As a compensating control pending patching, restrict local administrative access to the Tanium Module Server hosting Connect to the minimum required operators, using role-based access controls within Tanium and OS-level account restrictions. Audit which accounts hold elevated local access to that host. Consider reviewing Connect integration credentials stored in the platform and rotating any secrets that may have been exposed via process inspection. Note that restricting process visibility (e.g., hidepid mount options on Linux) can reduce exposure without requiring an immediate patch, though this may interfere with monitoring tooling.

CVE-2021-26715 CRITICAL POC
9.1 Mar 25

The OpenID Connect server implementation for MITREid Connect through 1.3.3 contains a Server Side Request Forgery (SSRF)

CVE-2021-27582 CRITICAL POC
9.1 Feb 23

org/mitre/oauth2/web/OAuthConfirmationController.java in the OpenID Connect server implementation for MITREid Connect th

CVE-2025-27203 CRITICAL
9.6 Jul 08

Arbitrary code execution in Adobe Connect 24.0 and earlier allows remote attackers to execute arbitrary code through des

CVE-2020-9442 HIGH POC
7.8 Feb 28

OpenVPN Connect 3.1.0.361 on Windows has Insecure Permissions for %PROGRAMDATA%\OpenVPN Connect\drivers\tap\amd64\win10,

CVE-2016-7851 MEDIUM POC
6.1 Nov 08

Adobe Connect version 9.5.6 and earlier does not adequately validate input in the events registration module. Rated medi

CVE-2017-11291 CRITICAL
10.0 Dec 09

An issue was discovered in Adobe Connect 9.6.2 and earlier versions. Rated critical severity (CVSS 10.0), this vulnerabi

CVE-2016-0949 CRITICAL
9.8 Feb 10

Adobe Connect before 9.5.2 allows remote attackers to have an unspecified impact via a crafted parameter in a URL. Rated

CVE-2022-38131 MEDIUM POC
6.1 Sep 06

RStudio Connect prior to 2023.01.0 is affected by an Open Redirect issue. Rated medium severity (CVSS 6.1), this vulnera

CVE-2020-5497 MEDIUM POC
6.1 Jan 04

The OpenID Connect reference implementation for MITREid Connect through 1.3.3 allows XSS due to userInfoJson being inclu

CVE-2023-4662 CRITICAL
9.8 Sep 15

Execution with Unnecessary Privileges vulnerability in Saphira Saphira Connect allows Remote Code Inclusion. Rated criti

CVE-2023-4661 CRITICAL
9.8 Sep 15

Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Saphira Saphira Co

CVE-2021-40719 CRITICAL
9.8 Oct 21

Adobe Connect version 11.2.3 (and earlier) is affected by a Deserialization of Untrusted Data vulnerability to achieve a

Share

CVE-2026-12139 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy