Ax3 Firmware
CVE-2025-69766
CRITICAL
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Lifecycle Timeline
3DescriptionCVE.org
Tenda AX3 firmware v16.03.12.11 contains a stack-based buffer overflow in the formGetIptv function due to improper handling of the citytag stack buffer, which may result in memory corruption and remote code execution.
AnalysisAI
Tenda AX3 firmware has a third stack-based buffer overflow in formGetIptv, allowing unauthenticated remote code execution through the router's web interface.
Technical ContextAI
The formGetIptv function in Tenda AX3 firmware v16.03.12.11 has a CWE-121 stack-based buffer overflow due to improper handling of input parameters, the third overflow discovered in IPTV-related handlers.
RemediationAI
Update firmware. Disable IPTV features if not used. Segment IoT/router management networks.
More in Ax3 Firmware
View allTenda AX3 v16.03.12.11 was discovered to contain a remote code execution (RCE) vulnerability via the list parameter at /
Tenda AX3 firmware has a second stack overflow in formSetIptv via the vlanId parameter, allowing remote code execution t
Tenda AX3 firmware v16.03.12.11 has a stack overflow in formSetIptv via the list parameter, enabling remote attackers to
Tenda AX3 firmware has another stack-based buffer overflow in formGetIptv through a different input path, enabling remot
Tenda AX3 V16.03.12.11 was discovered to contain a Command Execution vulnerability via the function /goform/telnet. Rate
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the function set_device_name. Rated critical sever
Tenda AX3 V16.03.12.11 was discovered to contain a command injection vulnerability via the lanip parameter at /goform/Ad
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the shareSpeed parameter at /goform/WifiGuestSet.
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the timeType function at /goform/SetSysTimeCfg. Ra
Tenda AX3 v16.03.12.10_CN was discovered to contain a stack overflow in the function fromSetSysTime. Rated critical seve
Tenda AX3 V16.03.12.11 is vulnerable to Buffer Overflow via /goform/SetFirewallCfg. Rated high severity (CVSS 8.8), this
Tenda AX3 firmware v16.03.12.11 contains a stack overflow in formGetIptv function and the list parameter, which can caus
Same weakness CWE-121 – Stack-based Buffer Overflow