Alert meAnalysisAIv1 – Mar 12, 2026
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected t...
Earlier versions of this analysis (1)
Ip7137 Firmware versions up to 0200a is affected by missing authentication for critical function (CVSS 7.5).
RemediationAI
Monitor vendor advisories for a patch. Restrict network access to the affected service where possible.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability (CWE-306: Missing Authentication for Critical Function) affects Ip7137 Firmware. Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to b
Know when Ip7137 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionCVE.org
Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Executive ViewAI
Organizations using Vivotek IP7137 camera with firmware version 0200a face notable risk from CVE-2025-66049, a missing authentication vulnerability rated CVSS 7.5. Attackers could bypass security controls to gain unauthorized access to protected resources and sensitive data. Organizations should apply vendor updates when available and consider compensating controls in the interim.
Apply vendor patch. If immediate patching is not feasible: (1) Implement network-level access controls; (2) Enable MFA where possible; (3) Monitor authentication logs for anomalous access.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
More in Ip7137 Firmware
View allVivotek IP7137 camera ships without any admin password by default, and users are not informed they should set one. End-o
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "
Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated a
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB