Skip to main content

Vivotek

22 CVEs vendor

Monthly

CVE-2026-35717 Jun 02, 14:16 MEDIUM This Month

Stack-based buffer overflow in VIVOTEK FD8136 network camera firmware FD8136-VVTK-0300a allows authenticated remote attackers to execute arbitrary code as root by sending a crafted POST request to the export_language.cgi administrative endpoint. The CGI handler passes an attacker-controlled Content-Length HTTP header value directly to fread() with no bounds validation, overflowing a 0x60-byte stack buffer and overwriting the saved link register; the binary's lack of stack canaries eliminates the primary runtime defense against this class of attack. A researcher-published proof-of-concept exists on GitHub, though EPSS stands at 0.05% (17th percentile) and the vulnerability is not currently listed in the CISA KEV catalog, suggesting no confirmed widespread exploitation at time of analysis.

RCE Buffer Overflow Stack Overflow Fd8136 Firmware Vivotek
NVD GitHub VulDB
CVSS 3.1
6.3
EPSS
0.1%
CVE-2025-66052 Jan 09, 12:15 HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. [CVSS 7.2 HIGH]

Command Injection Ip7137 Firmware Vivotek
NVD
CVSS 3.1
7.2
EPSS
0.3%
CVE-2025-66051 Jan 09, 12:15 MEDIUM This Month

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. [CVSS 6.5 MEDIUM]

Path Traversal Ip7137 Firmware Vivotek
NVD
CVSS 3.1
6.5
EPSS
0.0%
CVE-2025-66050 Jan 09, 12:15 CRITICAL Act Now

Vivotek IP7137 camera ships without any admin password by default, and users are not informed they should set one. End-of-life product with no expected fix – all deployed cameras are likely exposed.

Denial Of Service Ip7137 Firmware Vivotek
NVD
CVSS 3.1
9.8
EPSS
0.1%
CVE-2025-66049 Jan 09, 12:15 HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected t...

Information Disclosure Ip7137 Firmware Vivotek
NVD
CVSS 3.1
7.5
EPSS
0.1%
CVE-2024-7443 Aug 03, 19:15 MEDIUM This Month

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Ib8367A Firmware Vivotek
NVD VulDB
CVSS 4.0
5.3
EPSS
2.7%
CVE-2024-7442 Aug 03, 18:15 MEDIUM This Month

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Sd9364 Firmware Vivotek
NVD VulDB
CVSS 4.0
5.3
EPSS
2.7%
CVE-2024-7441 Aug 03, 18:15 HIGH This Week

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Sd9364 Firmware Vivotek
NVD VulDB
CVSS 4.0
8.7
EPSS
8.1%
CVE-2024-7440 Aug 03, 17:15 MEDIUM This Month

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Cc8160 Firmware Vivotek
NVD VulDB
CVSS 4.0
5.3
EPSS
2.7%
CVE-2024-7439 Aug 03, 16:15 HIGH This Week

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Cc8160 Firmware Vivotek
NVD VulDB
CVSS 4.0
8.7
EPSS
1.0%
CVE-2024-26548 Feb 29, 20:15 CRITICAL Act Now

An issue in vivotek Network Camera v.FD8166A-VVTK-0204j allows a remote attacker to execute arbitrary code via a crafted payload to the upload_file.cgi component. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Camera Firmware Vivotek
NVD GitHub
CVSS 3.1
9.8
EPSS
1.1%
CVE-2020-11950 May 28, 13:15 HIGH This Week

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Cc9381 Hv Firmware Fd9360 H Firmware Fd9368 Htv Firmware Fd9380 H Firmware +197
NVD
CVSS 3.1
8.8
EPSS
2.7%
CVE-2020-11949 May 28, 13:15 MEDIUM This Month

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera's. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Cc9381 Hv Firmware Fd9360 H Firmware Fd9368 Htv Firmware Fd9380 H Firmware +191
NVD
CVSS 3.1
6.5
EPSS
1.2%
CVE-2019-14458 Sep 18, 18:15 HIGH This Week

VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Camera Vivotek
NVD
CVSS 3.1
7.5
EPSS
1.9%
CVE-2019-10256 Sep 10, 19:15 CRITICAL Act Now

An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Camera Vivotek
NVD
CVSS 3.1
9.8
EPSS
1.3%
CVE-2019-14457 Sep 10, 18:15 CRITICAL Act Now

VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Memory Corruption Camera Vivotek
NVD
CVSS 3.1
9.8
EPSS
2.6%
CVE-2018-14771 Sep 05, 21:29 HIGH This Week

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RCE Camera Vivotek
NVD
CVSS 3.0
8.8
EPSS
3.0%
CVE-2018-14770 Sep 05, 21:29 HIGH This Week

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RCE Camera Vivotek
NVD
CVSS 3.0
8.8
EPSS
3.0%
CVE-2018-14769 Sep 05, 21:29 HIGH This Week

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

CSRF Camera Vivotek
NVD
CVSS 3.0
8.8
EPSS
0.5%
CVE-2018-14768 Aug 29, 19:29 HIGH This Week

Various VIVOTEK FD8*, FD9*, FE9*, IB8*, IB9*, IP9*, IZ9*, MS9*, SD9*, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RCE Camera Vivotek
NVD
CVSS 3.0
8.8
EPSS
2.9%
CVE-2017-9829 Jun 23, 22:29 HIGH This Week

'/cgi-bin/admin/downloadMedias.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera's Linux filesystem via a. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Path Traversal Network Camera Ib8369 Firmware Network Camera Fd8164 Firmware Network Camera Fd816Ba Firmware Vivotek
NVD
CVSS 3.0
7.5
EPSS
5.9%
CVE-2017-9828 Jun 23, 22:29 CRITICAL Emergency

'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Epss exploitation probability 58.3% and no vendor patch available.

Command Injection Network Camera Ib8369 Firmware Network Camera Fd8164 Firmware Network Camera Fd816Ba Firmware Vivotek
NVD
CVSS 3.0
9.8
EPSS
58.3%
EPSS 0% CVSS 6.3
MEDIUM This Month

Stack-based buffer overflow in VIVOTEK FD8136 network camera firmware FD8136-VVTK-0300a allows authenticated remote attackers to execute arbitrary code as root by sending a crafted POST request to the export_language.cgi administrative endpoint. The CGI handler passes an attacker-controlled Content-Length HTTP header value directly to fread() with no bounds validation, overflowing a 0x60-byte stack buffer and overwriting the saved link register; the binary's lack of stack canaries eliminates the primary runtime defense against this class of attack. A researcher-published proof-of-concept exists on GitHub, though EPSS stands at 0.05% (17th percentile) and the vulnerability is not currently listed in the CISA KEV catalog, suggesting no confirmed widespread exploitation at time of analysis.

RCE Buffer Overflow Stack Overflow +2
NVD GitHub VulDB
EPSS 0% CVSS 7.2
HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. [CVSS 7.2 HIGH]

Command Injection Ip7137 Firmware Vivotek
NVD
EPSS 0% CVSS 6.5
MEDIUM This Month

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. [CVSS 6.5 MEDIUM]

Path Traversal Ip7137 Firmware Vivotek
NVD
EPSS 0% CVSS 9.8
CRITICAL Act Now

Vivotek IP7137 camera ships without any admin password by default, and users are not informed they should set one. End-of-life product with no expected fix – all deployed cameras are likely exposed.

Denial Of Service Ip7137 Firmware Vivotek
NVD
EPSS 0% CVSS 7.5
HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected t...

Information Disclosure Ip7137 Firmware Vivotek
NVD
EPSS 3% CVSS 5.3
MEDIUM This Month

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability classified as critical has been found in Vivotek IB8367A VVTK-0100b. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Ib8367A Firmware Vivotek
NVD VulDB
EPSS 3% CVSS 5.3
MEDIUM This Month

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Sd9364 Firmware Vivotek
NVD VulDB
EPSS 8% CVSS 8.7
HIGH This Week

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek SD9364 VVTK-0103f. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Sd9364 Firmware +1
NVD VulDB
EPSS 3% CVSS 5.3
MEDIUM This Month

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Cc8160 Firmware Vivotek
NVD VulDB
EPSS 1% CVSS 8.7
HIGH This Week

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in Vivotek CC8160 VVTK-0100d and classified as critical. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Buffer Overflow Stack Overflow Cc8160 Firmware +1
NVD VulDB
EPSS 1% CVSS 9.8
CRITICAL Act Now

An issue in vivotek Network Camera v.FD8166A-VVTK-0204j allows a remote attacker to execute arbitrary code via a crafted payload to the upload_file.cgi component. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RCE Camera Firmware Vivotek
NVD GitHub
EPSS 3% CVSS 8.8
HIGH This Week

VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to upload and execute a script (with resultant execution of OS commands). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Command Injection Cc9381 Hv Firmware Fd9360 H Firmware +199
NVD
EPSS 1% CVSS 6.5
MEDIUM This Month

testserver.cgi of the web service on VIVOTEK Network Cameras before XXXXX-VVTK-2.2002.xx.01x (and before XXXXX-VVTK-0XXXX_Beta2) allows an authenticated user to obtain arbitrary files from a camera's. Rated medium severity (CVSS 6.5), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Information Disclosure Cc9381 Hv Firmware Fd9360 H Firmware +193
NVD
EPSS 2% CVSS 7.5
HIGH This Week

VIVOTEK IP Camera devices with firmware before 0x20x allow a denial of service via a crafted HTTP header. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Denial Of Service Camera Vivotek
NVD
EPSS 1% CVSS 9.8
CRITICAL Act Now

An authentication bypass vulnerability in VIVOTEK IPCam versions prior to 0x13a was found. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Authentication Bypass Camera Vivotek
NVD
EPSS 3% CVSS 9.8
CRITICAL Act Now

VIVOTEK IP Camera devices with firmware before 0x20x have a stack-based buffer overflow via a crafted HTTP header. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Buffer Overflow Memory Corruption Camera +1
NVD
EPSS 3% CVSS 8.8
HIGH This Week

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 2 of 2) via eventscript.cgi. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RCE Camera Vivotek
NVD
EPSS 3% CVSS 8.8
HIGH This Week

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code (issue 1 of 2) via the ONVIF interface, (/onvif/device_service). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RCE Camera Vivotek
NVD
EPSS 0% CVSS 8.8
HIGH This Week

VIVOTEK FD8177 devices before XXXXXX-VVTK-xx06a allow CSRF. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

CSRF Camera Vivotek
NVD
EPSS 3% CVSS 8.8
HIGH This Week

Various VIVOTEK FD8*, FD9*, FE9*, IB8*, IB9*, IP9*, IZ9*, MS9*, SD9*, and other devices before XXXXXX-VVTK-xx06a allow remote attackers to execute arbitrary code. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

RCE Camera Vivotek
NVD
EPSS 6% CVSS 7.5
HIGH This Week

'/cgi-bin/admin/downloadMedias.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable, which allows remote attackers to read any file on the camera's Linux filesystem via a. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Path Traversal Network Camera Ib8369 Firmware Network Camera Fd8164 Firmware +2
NVD
EPSS 58% CVSS 9.8
CRITICAL Emergency

'/cgi-bin/admin/testserver.cgi' of the web service in most of the VIVOTEK Network Cameras is vulnerable to shell command injection, which allows remote attackers to execute any shell command as root. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Epss exploitation probability 58.3% and no vendor patch available.

Command Injection Network Camera Ib8369 Firmware Network Camera Fd8164 Firmware +2
NVD

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy