Skip to main content

Sd9364 Firmware CVE-2024-7442

MEDIUM
Command Injection (CWE-77)
2024-08-03 cna@vuldb.com
5.3
CVSS 4.0 · Vendor: vuldb
Share

Severity by source

Vendor (vuldb) PRIMARY
5.3 MEDIUM
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Primary rating from Vendor (vuldb) · only source for this CVE.

CVSS VectorVendor: vuldb

CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
X

Lifecycle Timeline

1
CVE Published
Aug 03, 2024 - 18:15 cve.org
MEDIUM 5.3

DescriptionCVE.org

UNSUPPORTED WHEN ASSIGNED A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical. This issue affects the function getenv of the file upload_file.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life.

AnalysisAI

UNSUPPORTED WHEN ASSIGNED A vulnerability was found in Vivotek SD9364 VVTK-0103f. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. UNSUPPORTED WHEN ASSIGNED A vulnerability was found in Vivotek SD9364 VVTK-0103f. It has been rated as critical.cgi. The manipulation of the argument QUERY_STRING leads to command injection. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-273527. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed that the affected release tree is end-of-life. Affected products include: Vivotek Sd9364 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.

Share

CVE-2024-7442 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy