Ip7137 Firmware

4 CVEs product

Monthly

CVE-2025-66052 HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. [CVSS 7.2 HIGH]

Command Injection Ip7137 Firmware
NVD
CVSS 3.1
7.2
EPSS
0.3%
CVE-2025-66051 MEDIUM This Month

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. [CVSS 6.5 MEDIUM]

Path Traversal Ip7137 Firmware
NVD
CVSS 3.1
6.5
EPSS
0.0%
CVE-2025-66050 CRITICAL Act Now

Vivotek IP7137 camera ships without any admin password by default, and users are not informed they should set one. End-of-life product with no expected fix – all deployed cameras are likely exposed.

Denial Of Service Ip7137 Firmware
NVD
CVSS 3.1
9.8
EPSS
0.1%
CVE-2025-66049 HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected t...

Information Disclosure Ip7137 Firmware
NVD
CVSS 3.1
7.5
EPSS
0.1%
CVE-2025-66052
EPSS 0% CVSS 7.2
HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. [CVSS 7.2 HIGH]

Command Injection Ip7137 Firmware
NVD
CVE-2025-66051
EPSS 0% CVSS 6.5
MEDIUM This Month

Vivotek IP7137 camera with firmware version 0200a is vulnerable to path traversal. It is possible for an authenticated attacker to access resources beyond webroot directory using a direct HTTP request. [CVSS 6.5 MEDIUM]

Path Traversal Ip7137 Firmware
NVD
CVE-2025-66050
EPSS 0% CVSS 9.8
CRITICAL Act Now

Vivotek IP7137 camera ships without any admin password by default, and users are not informed they should set one. End-of-life product with no expected fix – all deployed cameras are likely exposed.

Denial Of Service Ip7137 Firmware
NVD
CVE-2025-66049
EPSS 0% CVSS 7.5
HIGH This Week

Vivotek IP7137 camera with firmware version 0200a is vulnerable to an information disclosure issue where live camera footage can be accessed through the RTSP protocol on port 8554 without requiring authentication. This allows unauthorized users with network access to view the camera's feed, potentially compromising user privacy and security.  The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected t...

Information Disclosure Ip7137 Firmware
NVD

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy