Ac6 Firmware
CVE-2025-24496
HIGH
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Lifecycle Timeline
2DescriptionCVE.org
An information disclosure vulnerability exists in the /goform/getproductInfo functionality of Tenda AC6 V5.0 V02.03.01.110. Specially crafted network packets can lead to a disclosure of sensitive information. An attacker can send packets to trigger this vulnerability.
AnalysisAI
An information disclosure vulnerability exists in the /goform/getproductInfo functionality of Tenda AC6 V5.0 V02.03.01.110. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-288. An information disclosure vulnerability exists in the /goform/getproductInfo functionality of Tenda AC6 V5.0 V02.03.01.110. Specially crafted network packets can lead to a disclosure of sensitive information. An attacker can send packets to trigger this vulnerability. Affected products include: Tenda Ac6 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Ac6 Firmware
View allTenda AC6 v2.0 v15.03.06.50 was discovered to contain a buffer overflow in the function 'fromSetSysTime. Rated critical
Tenda AC6 V15.03.05.16 firmware has a buffer overflow vulnerability in the formexeCommand function. Rated critical sever
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the fromAddressNat function. Rated critical sever
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formWifiWpsOOB function. Rated critical sever
Tenda AC6 v15.03.05.16 was discovered to contain a buffer overflow via the formSetSpeedWan function. Rated critical seve
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin function 'sub_3A1D0' contains a command execution vulnerability. Rate
Tenda AC6 US_AC6V1.0BR_V15.03.05.16_multi_TD01.bin is vulnerable to Buffer Overflow via function sub_90998. Rated critic
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28,
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1
A vulnerability classified as critical was found in Tenda AC6 US_AC6V1.0BR_V15.03.05.19. Rated critical severity (CVSS 9
Same technique Information Disclosure
View allShare
External POC / Exploit Code
Leaving vuln.today