Severity by source
CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Adjacent network vector and low-privilege requirement match the vendor-supplied CVSS 4.0 vector; unchanged scope reflects SC:N/SI:N/SA:N in the 4.0 data.
Primary rating from Vendor (Rockwell).
CVSS VectorVendor: Rockwell
Lifecycle Timeline
2DescriptionCVE.org
A security issue exists within FactoryTalk® Historian Machine Edition. An attacker with low-level authentication could exploit this vulnerability to achieve remote code execution on the affected device.
AnalysisAI
Remote code execution in Rockwell Automation FactoryTalk® Historian Machine Edition allows an adjacent-network attacker holding low-privilege credentials to fully compromise the historian host via a memory corruption flaw. The root cause is CWE-787 (Out-of-bounds Write), consistent with a buffer overflow in the historian's network-facing service, yielding full confidentiality, integrity, and availability impact on the affected device. No active exploitation has been confirmed in CISA KEV and no public proof-of-concept has been identified at the time of analysis.
Technical ContextAI
FactoryTalk® Historian Machine Edition is Rockwell Automation's OT/ICS time-series data historian, used to collect and archive process data from industrial control systems such as PLCs and SCADA devices. The affected CPE - cpe:2.3:a:rockwell_automation:factorytalk®_historian_machine_edition:*:*:*:*:*:*:*:* - lists all versions as affected with no version floor published. CWE-787 (Out-of-bounds Write) identifies the root cause as a memory safety failure, most commonly manifesting as a classic stack or heap buffer overflow in network input parsing routines. In OT historian software, such services frequently run with elevated system privileges and are persistently reachable from engineering workstations on the OT segment, making memory corruption particularly high-impact in this deployment context.
RemediationAI
Consult Rockwell Automation Security Advisory SD1796 at https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1796.html for the vendor-released patch and exact fixed version - no specific patched version number was independently confirmable from the available input data, so the advisory is the authoritative source for upgrade instructions. As an interim compensating control, enforce strict OT network segmentation to ensure only authorized engineering workstations can reach the FactoryTalk Historian service port; this addresses the AV:A exposure but does not protect against insider threats or post-breach lateral movement. Additionally, audit and minimize the number of accounts holding any level of credential access to the historian service, reducing the pool of credentials that could satisfy the PR:L requirement. Monitor for unexpected process crashes or memory-fault events on historian hosts, which may indicate unsuccessful exploit attempts.
Same weakness CWE-787 – Out-of-bounds Write
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2025-210818
GHSA-f7wq-9ch9-3gvp