Skip to main content

Azure Access BLU-IC2 CVE-2025-12363

CRITICAL
Information Exposure (CWE-200)
2025-10-27 a0340c66-c385-4f8b-991b-3d05f6fd5220
10.0
CVSS 4.0 · Vendor: a0340c66-c385-4f8b-991b-3d05f6fd5220
View

Attack ChainAIDerived

Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain

  1. Access
    Reach intercom over network
  2. Delivery
    Query credential-disclosing endpoint
  3. Exploit
    Retrieve cleartext email password
  4. Execution
    Authenticate to email account
  5. Impact
    Pivot to connected services

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK

2 techniques across 2 tactics: Collection, Discovery

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Exploitation Conditions

Exploitation requires network reachability to a BLU-IC2 or BLU-IC4 intercom running firmware 1.19.5 or earlier that has an email/SMTP account configured - the disclosed secret only exists on devices where email notification is set up, so units with no email account configured are not exposed. Per the CVSS vector (AV:N/AC:L/AT:N/PR:N/UI:N) no authentication, special attack requirement, or user interaction is needed, making any device whose management/notification interface is reachable by the attacker directly exploitable. The primary limiting factors are therefore network exposure of these access-control appliances (typically on segmented internal or building-automation networks rather than the public internet) and whether the email-disclosure feature is in use.

Impact

Signals conflict sharply and must be weighed carefully. The vendor-supplied CVSS 4.0 vector scores a maximal 10.0 with AV:N/AC:L/AT:N/PR:N/UI:N and full High impact on both the vulnerable system (VC/VI/VA:H) and subsequent systems (SC/SI/SA:H), implying trivially remote, unauthenticated, total compromise. However, the CWE-200 classification and the terse description ('Email Password Disclosure') describe an information-exposure flaw whose direct impact is confidentiality of stored email credentials - the full Integrity/Availability High ratings appear to be the vendor accounting for downstream pivoting (using the leaked mailbox password) rather than a direct I/A effect of the vulnerability itself, so the 10.0 likely overstates direct technical impact. Countervailing real-world signals are weak: EPSS is just 0.32% (23rd percentile), there is no CISA KEV listing and no public exploit identified, indicating no evidence of exploitation despite the perfect CVSS. Net: treat as a genuinely serious credential-disclosure bug on an internet-exposable access-control device (patchable by upgrading past 1.19.5), but prioritize below products with comparable CVSS that also carry KEV/POC/high-EPSS signals. Note explicitly: description implies a single disclosed secret while CVSS claims full CIA on two system tiers - verify the real impact scope against the vendor advisory.

Exploit ScenarioDerived

An attacker with network reach to an exposed BLU-IC2/BLU-IC4 intercom (firmware ≤1.19.5) requests or reads a device endpoint that returns the configured email account password in cleartext, requiring no authentication or user interaction (AV:N/PR:N/UI:N). The attacker then logs into that email account to read mail, send spoofed messages, or reset other services tied to the address. No public proof-of-concept is identified at time of analysis, so weaponization effort is unverified.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAIv1 – Oct 18, 2026

Email/SMTP password disclosure in Azure Access BLU-IC2 and BLU-IC4 intercom firmware through 1.19.5 allows unauthenticated remote attackers with network reachability to retrieve stored email account credentials, but only on units where an email/SMTP account is configured. No public exploit code was identified at time of analysis, and EPSS is low at 0.32% (23rd percentile). The reported CVSS 4.0 score of 10.0 conflicts with the assessed CVSS 3.1 confidentiality-only impact (C:H/I:N/A:N) and with the practical prerequisites of network exposure and a configured email account.

RemediationAI

No vendor-released patch with an exact fixed version is identified in the provided data; consult the vendor advisory at https://azure-access.com/security-advisories for updated firmware and apply the fixed release when available. Until then, restrict network access to the BLU-IC2/BLU-IC4 management and notification interfaces to trusted VLANs or firewall allowlists - this may limit legitimate remote administration. If email notification is not required, disable the email/SMTP configuration on affected devices, which removes the stored secret but also disables email alerting. Where email must remain enabled, rotate the SMTP account password and use a dedicated low-privilege account so that disclosure does not compromise broader credentials. Monitor device logs for unauthenticated access to management endpoints and anomalous credential-retrieval attempts.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

The affected components are the firmware images for Azure Access BLU-IC2 and BLU-IC4 access-control intercoms, identified by CPE entries cpe:2.3:o:azure-access:blu-ic2_firmware:*:*:*:*:*:*:*:* and cpe:2.3:o:azure-access:blu-ic4_firmware:*:*:*:*:*:*:*:*. CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor) indicates that the email/SMTP password used for notification delivery is not adequately protected against retrieval by an unauthorized party. The CVSS vector is AV:N/AC:L/PR:N/UI:N, so an attacker needs only network reachability to the device's management/notification interface - no authentication or user interaction - and can then obtain the stored SMTP secret. The exposure is conditional: the secret exists only when email notification has been configured, so devices without an SMTP account do not carry the credential. The assessed impact is confidentiality-only (C:H/I:N/A:N), and the primary mitigating factor is that these intercoms are typically deployed on segmented internal or building-automation networks rather than the public internet.

Know when Blu Ic2 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

Vendor (a0340c66-c385-4f8b-991b-3d05f6fd5220) PRIMARY 10.0 CRITICAL
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
vuln.today AI 8.6 HIGH

Remote, unauthenticated, low-complexity disclosure of stored email credentials is a confidentiality breach (C:H); S:C reflects that leaked credentials compromise a separate email system; no direct integrity/availability impact.

3.1 AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N
4.0 AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:N/SA:N

Primary rating from Vendor (a0340c66-c385-4f8b-991b-3d05f6fd5220).

CVSS VectorVendor: a0340c66-c385-4f8b-991b-3d05f6fd5220

Attack Vector
Network
Attack Complexity
Low
Attack Requirements
None
Privileges Required
None
User Interaction
None
Vulnerable system: Confidentiality
High
Vulnerable system: Integrity
High
Vulnerable system: Availability
High
Subsequent system: Confidentiality
High
Subsequent system: Integrity
High
Subsequent system: Availability
High

DescriptionCVE.org

Email Password Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.

Executive ViewAI

Why It Matters

Azure Access BLU-IC2 and BLU-IC4 intercoms running firmware through 1.19.5 can expose stored email/SMTP credentials to network-reachable attackers, potentially enabling email account takeover and downstream phishing or business email compromise where those accounts are configured. Leadership should care because the issue is rated critical, but exploitation currently requires network reachability and a configured email account, and no public exploit identified at time of analysis.

Business Impact: Medium
Compensating Controls

No vendor-released patch identified at time of analysis. Interim mitigations include restricting network reachability to trusted management networks, disabling or removing stored SMTP/email account configuration where possible, rotating affected email credentials, segmenting intercom devices, and monitoring for credential misuse and vendor release of fixed firmware.

Threat Intelligence Overview

EPSS Score
0.3%
Top 77% exploitable
Prevalence
Low
niche access-control intercom hardware, limited industry-specific deployment
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 0.3%
Patch available No
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact
Medium

Priority Score

50
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +50
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)CVE.org

cpe:2.3:o:azure-access:blu-ic2_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:azure-access:blu-ic4_firmware:*:*:*:*:*:*:*:*
CVE-2025-12275 CRITICAL
10.0 Oct 26

Unauthenticated remote command execution affects Azure Access BLU-IC2 and BLU-IC4 firmware through version 1.19.5, where

CVE-2025-12422 CRITICAL
10.0 Oct 28

Arbitrary file write via path traversal in the firmware upgrade feature of Azure Access BLU-IC2 and BLU-IC4 boards (firm

CVE-2025-12104 CRITICAL
10.0 Oct 23

Outdated third-party UI dependencies in BLU-IC2 and BLU-IC4 firmware through 1.19.5 can expose the management web interf

CVE-2025-12220 CRITICAL
10.0 Oct 25

Network-reachable BLU-IC2 and BLU-IC4 devices running firmware through 1.19.5 embed BusyBox 1.31.1 and are exposed to mu

CVE-2025-12219 CRITICAL
10.0 Oct 25

Azure Access OS firmware through 1.19.5 on BLU-IC2 and BLU-IC4 physical access controllers contains unspecified vulnerab

CVE-2025-11832 CRITICAL
10.0 Oct 15

Denial-of-service conditions in Azure Access Technology BLU-IC2 and BLU-IC4 firmware through 1.19.5 allow remote attacke

CVE-2025-12477 CRITICAL
10.0 Oct 29

Unauthenticated remote attackers can retrieve server version information from Azure Access BLU-IC2 and BLU-IC4 physical

CVE-2025-12476 CRITICAL
10.0 Oct 29

Unauthenticated remote access to a critical function in Azure Access BLU-IC2/IC4 firmware through 1.19.5 lets a network

CVE-2025-12424 CRITICAL
10.0 Oct 28

Local privilege escalation in Azure Access BLU-IC2 and BLU-IC4 intercom firmware through 1.19.5 allows a lower-privilege

CVE-2025-12364 CRITICAL
10.0 Oct 27

Weak password policy in Azure Access BLU-IC2 and BLU-IC4 intercom access controller firmware through version 1.19.5 can

CVE-2025-12285 CRITICAL
10.0 Oct 26

BLU-IC2 and BLU-IC4 access-control/intercom units running firmware 1.19.5 or earlier ship with a factory default passwor

CVE-2025-12176 CRITICAL
10.0 Oct 24

BLU-IC2 and BLU-IC4 firmware through 1.19.5 contain undocumented administrative accounts that allow network-reachable at

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy