Azure Access BLU-IC2 CVE-2025-12363
CRITICALAttack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessReach intercom over network
-
DeliveryQuery credential-disclosing endpoint
-
ExploitRetrieve cleartext email password
-
ExecutionAuthenticate to email account
-
ImpactPivot to connected services
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V14 - Data Protection Data exposure prevention
MITRE ATT&CK
2 techniques across 2 tactics: Collection, Discovery The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Exploitation Conditions | Exploitation requires network reachability to a BLU-IC2 or BLU-IC4 intercom running firmware 1.19.5 or earlier that has an email/SMTP account configured - the disclosed secret only exists on devices where email notification is set up, so units with no email account configured are not exposed. Per the CVSS vector (AV:N/AC:L/AT:N/PR:N/UI:N) no authentication, special attack requirement, or user interaction is needed, making any device whose management/notification interface is reachable by the attacker directly exploitable. The primary limiting factors are therefore network exposure of these access-control appliances (typically on segmented internal or building-automation networks rather than the public internet) and whether the email-disclosure feature is in use. |
| Impact | Signals conflict sharply and must be weighed carefully. The vendor-supplied CVSS 4.0 vector scores a maximal 10.0 with AV:N/AC:L/AT:N/PR:N/UI:N and full High impact on both the vulnerable system (VC/VI/VA:H) and subsequent systems (SC/SI/SA:H), implying trivially remote, unauthenticated, total compromise. However, the CWE-200 classification and the terse description ('Email Password Disclosure') describe an information-exposure flaw whose direct impact is confidentiality of stored email credentials - the full Integrity/Availability High ratings appear to be the vendor accounting for downstream pivoting (using the leaked mailbox password) rather than a direct I/A effect of the vulnerability itself, so the 10.0 likely overstates direct technical impact. Countervailing real-world signals are weak: EPSS is just 0.32% (23rd percentile), there is no CISA KEV listing and no public exploit identified, indicating no evidence of exploitation despite the perfect CVSS. Net: treat as a genuinely serious credential-disclosure bug on an internet-exposable access-control device (patchable by upgrading past 1.19.5), but prioritize below products with comparable CVSS that also carry KEV/POC/high-EPSS signals. Note explicitly: description implies a single disclosed secret while CVSS claims full CIA on two system tiers - verify the real impact scope against the vendor advisory. |
| Exploit ScenarioDerived | An attacker with network reach to an exposed BLU-IC2/BLU-IC4 intercom (firmware ≤1.19.5) requests or reads a device endpoint that returns the configured email account password in cleartext, requiring no authentication or user interaction (AV:N/PR:N/UI:N). The attacker then logs into that email account to read mail, send spoofed messages, or reset other services tied to the address. No public proof-of-concept is identified at time of analysis, so weaponization effort is unverified. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv1 – Oct 18, 2026
Email/SMTP password disclosure in Azure Access BLU-IC2 and BLU-IC4 intercom firmware through 1.19.5 allows unauthenticated remote attackers with network reachability to retrieve stored email account credentials, but only on units where an email/SMTP account is configured. No public exploit code was identified at time of analysis, and EPSS is low at 0.32% (23rd percentile). The reported CVSS 4.0 score of 10.0 conflicts with the assessed CVSS 3.1 confidentiality-only impact (C:H/I:N/A:N) and with the practical prerequisites of network exposure and a configured email account.
RemediationAI
No vendor-released patch with an exact fixed version is identified in the provided data; consult the vendor advisory at https://azure-access.com/security-advisories for updated firmware and apply the fixed release when available. Until then, restrict network access to the BLU-IC2/BLU-IC4 management and notification interfaces to trusted VLANs or firewall allowlists - this may limit legitimate remote administration. If email notification is not required, disable the email/SMTP configuration on affected devices, which removes the stored secret but also disables email alerting. Where email must remain enabled, rotate the SMTP account password and use a dedicated low-privilege account so that disclosure does not compromise broader credentials. Monitor device logs for unauthenticated access to management endpoints and anomalous credential-retrieval attempts.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
The affected components are the firmware images for Azure Access BLU-IC2 and BLU-IC4 access-control intercoms, identified by CPE entries cpe:2.3:o:azure-access:blu-ic2_firmware:*:*:*:*:*:*:*:* and cpe:2.3:o:azure-access:blu-ic4_firmware:*:*:*:*:*:*:*:*. CWE-200 (Exposure of Sensitive Information to an Unauthorized Actor) indicates that the email/SMTP password used for notification delivery is not adequately protected against retrieval by an unauthorized party. The CVSS vector is AV:N/AC:L/PR:N/UI:N, so an attacker needs only network reachability to the device's management/notification interface - no authentication or user interaction - and can then obtain the stored SMTP secret. The exposure is conditional: the secret exists only when email notification has been configured, so devices without an SMTP account do not carry the credential. The assessed impact is confidentiality-only (C:H/I:N/A:N), and the primary mitigating factor is that these intercoms are typically deployed on segmented internal or building-automation networks rather than the public internet.
Know when Blu Ic2 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Remote, unauthenticated, low-complexity disclosure of stored email credentials is a confidentiality breach (C:H); S:C reflects that leaked credentials compromise a separate email system; no direct integrity/availability impact.
Primary rating from Vendor (a0340c66-c385-4f8b-991b-3d05f6fd5220).
CVSS VectorVendor: a0340c66-c385-4f8b-991b-3d05f6fd5220
DescriptionCVE.org
Email Password Disclosure.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.
Executive ViewAI
Azure Access BLU-IC2 and BLU-IC4 intercoms running firmware through 1.19.5 can expose stored email/SMTP credentials to network-reachable attackers, potentially enabling email account takeover and downstream phishing or business email compromise where those accounts are configured. Leadership should care because the issue is rated critical, but exploitation currently requires network reachability and a configured email account, and no public exploit identified at time of analysis.
No vendor-released patch identified at time of analysis. Interim mitigations include restricting network reachability to trusted management networks, disabling or removing stored SMTP/email account configuration where possible, rotating affected email credentials, segmenting intercom devices, and monitoring for credential misuse and vendor release of fixed firmware.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)CVE.org
More in Blu Ic2 Firmware
View allUnauthenticated remote command execution affects Azure Access BLU-IC2 and BLU-IC4 firmware through version 1.19.5, where
Arbitrary file write via path traversal in the firmware upgrade feature of Azure Access BLU-IC2 and BLU-IC4 boards (firm
Outdated third-party UI dependencies in BLU-IC2 and BLU-IC4 firmware through 1.19.5 can expose the management web interf
Network-reachable BLU-IC2 and BLU-IC4 devices running firmware through 1.19.5 embed BusyBox 1.31.1 and are exposed to mu
Azure Access OS firmware through 1.19.5 on BLU-IC2 and BLU-IC4 physical access controllers contains unspecified vulnerab
Denial-of-service conditions in Azure Access Technology BLU-IC2 and BLU-IC4 firmware through 1.19.5 allow remote attacke
Unauthenticated remote attackers can retrieve server version information from Azure Access BLU-IC2 and BLU-IC4 physical
Unauthenticated remote access to a critical function in Azure Access BLU-IC2/IC4 firmware through 1.19.5 lets a network
Local privilege escalation in Azure Access BLU-IC2 and BLU-IC4 intercom firmware through 1.19.5 allows a lower-privilege
Weak password policy in Azure Access BLU-IC2 and BLU-IC4 intercom access controller firmware through version 1.19.5 can
BLU-IC2 and BLU-IC4 access-control/intercom units running firmware 1.19.5 or earlier ship with a factory default passwor
BLU-IC2 and BLU-IC4 firmware through 1.19.5 contain undocumented administrative accounts that allow network-reachable at
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB