Fh1206 Firmware
CVE-2024-42979
HIGH
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, write limits
MITRE ATT&CK
2 techniques across 2 tactics: Execution, Privilege Escalation The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | A remote attacker could write data beyond allocated buffer boundaries leading to code execution or crashes by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request. Affected products include: Tenda Fh1206 Firmware.
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Memory corruption occurs when a program writes data beyond the boundaries of allocated memory regions or accesses memory in unintended ways, violating the integrity of the process's address space.
Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.
Affected Products (CPE)NVD
More in Fh1206 Firmware
View allAn issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary co
Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the mac parameter at ip/gofo
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPW paramet
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parame
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterfac
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset. Rated high seve
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 p
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 p
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. Rated high severity (CVSS 8.8), this
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Rated high severity (CVSS 8.7), this v
A vulnerability was found in Tenda FH1206 1.2.0.8. Rated high severity (CVSS 8.7), this vulnerability is remotely exploi
A vulnerability was found in Tenda FH1206 1.2.0.8(8155). Rated high severity (CVSS 8.7), this vulnerability is remotely
NVD
CVE.org
EPSS
GitHub
Exploit-DB