Skip to main content

Fh1206 Firmware CVE-2024-35339

CRITICAL
Code Injection (CWE-94)
2024-05-24 cve@mitre.org
9.8
CVSS 3.1 · Vendor: mitre
Share

Severity by source

Vendor (mitre) PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from Vendor (mitre) · only source for this CVE.

CVSS VectorVendor: mitre

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
May 24, 2024 - 15:15 cve.org
CRITICAL 9.8

DescriptionCVE.org

Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac.

AnalysisAI

Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified as Code Injection (CWE-94), which allows attackers to inject and execute arbitrary code within the application. Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the mac parameter at ip/goform/WriteFacMac. Affected products include: Tenda Fh1206 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Never evaluate user-controlled input as code. Use sandboxing, disable dangerous functions, apply strict input validation.

CVE-2024-42978 CRITICAL POC
9.8 Aug 15

An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary co

CVE-2024-34945 CRITICAL POC
9.8 May 14

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPW paramet

CVE-2024-34943 CRITICAL POC
9.8 May 14

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parame

CVE-2024-33215 CRITICAL POC
9.8 Apr 23

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterfac

CVE-2024-44390 HIGH POC
8.8 Aug 23

Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset. Rated high seve

CVE-2024-34942 HIGH POC
8.8 May 14

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 p

CVE-2024-33212 HIGH POC
8.8 Apr 23

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 p

CVE-2024-4020 HIGH POC
8.8 Apr 20

A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. Rated high severity (CVSS 8.8), this

CVE-2024-7707 HIGH POC
8.7 Aug 13

A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Rated high severity (CVSS 8.7), this v

CVE-2024-7615 HIGH POC
8.7 Aug 12

A vulnerability was found in Tenda FH1206 1.2.0.8. Rated high severity (CVSS 8.7), this vulnerability is remotely exploi

CVE-2024-7614 HIGH POC
8.7 Aug 12

A vulnerability was found in Tenda FH1206 1.2.0.8(8155). Rated high severity (CVSS 8.7), this vulnerability is remotely

CVE-2024-7613 HIGH POC
8.7 Aug 12

A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. Rated high severity (CVSS 8.7), this

Share

CVE-2024-35339 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy