Fh1206 Firmware
CVE-2024-7707
HIGH
Severity by source
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Primary rating from Vendor (vuldb) · only source for this CVE.
CVSS VectorVendor: vuldb
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Lifecycle Timeline
1DescriptionCVE.org
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
AnalysisAI
A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Rated high severity (CVSS 8.7), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.
Technical ContextAI
This vulnerability is classified under CWE-121. A vulnerability was found in Tenda FH1206 02.03.01.35 and classified as critical. Affected by this issue is the function formSafeEmailFilter of the file /goform/SafeEmailFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Fh1206 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
More in Fh1206 Firmware
View allAn issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary co
Tenda FH1206 V1.2.0.8(8155) was discovered to contain a command injection vulnerability via the mac parameter at ip/gofo
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPW paramet
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parame
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterfac
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset. Rated high seve
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 p
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 p
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. Rated high severity (CVSS 8.8), this
A vulnerability was found in Tenda FH1206 1.2.0.8. Rated high severity (CVSS 8.7), this vulnerability is remotely exploi
A vulnerability was found in Tenda FH1206 1.2.0.8(8155). Rated high severity (CVSS 8.7), this vulnerability is remotely
A vulnerability was found in Tenda FH1206 1.2.0.8(8155) and classified as critical. Rated high severity (CVSS 8.7), this
Same weakness CWE-121 – Stack-based Buffer Overflow
View allSame technique Buffer Overflow