Skip to main content

Ac500 Firmware CVE-2024-3910

HIGH
Stack-based Buffer Overflow (CWE-121)
2024-04-17 cna@vuldb.com
8.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Apr 17, 2024 - 12:15 nvd
HIGH 8.8

DescriptionNVD

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

AnalysisAI

A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, low attack complexity. Public exploit code available and no vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-121. A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Affected by this issue is the function fromDhcpListClient of the file /goform/DhcpListClient. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-261146 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Ac500 Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2024-32318 CRITICAL POC
9.8 Apr 17

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo fun

CVE-2024-3908 CRITICAL POC
9.8 Apr 17

A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8),

CVE-2024-3907 CRITICAL POC
9.8 Apr 17

A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this vulnerability is remote

CVE-2023-25234 CRITICAL POC
9.8 Feb 27

Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInte

CVE-2023-25233 CRITICAL POC
9.8 Feb 27

Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInt

CVE-2025-7586 HIGH POC
8.8 Jul 14

A buffer overflow vulnerability in A vulnerability (CVSS 8.8). Risk factors: public PoC available.

CVE-2024-3906 HIGH POC
8.8 Apr 17

A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e

CVE-2024-3905 HIGH POC
8.8 Apr 17

A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e

CVE-2023-25235 HIGH POC
7.5 Feb 27

Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid. Rated high

CVE-2024-32316 MEDIUM POC
6.5 Apr 17

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. Rated medium

CVE-2024-32320 MEDIUM POC
5.9 Apr 17

Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone

CVE-2024-3909 CRITICAL
9.8 Apr 17

A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this

Share

CVE-2024-3910 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy