Ac500 Firmware
CVE-2024-3908
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Command injection prevention
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. Public proof-of-concept exploit code is available. |
| Exploit ScenarioDerived | A remote attacker could inject arbitrary commands into system command execution by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. Public exploit code available and no vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Use parameterized APIs, avoid shell execution, validate input with strict allowlists.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Command Injection (CWE-77), which allows attackers to inject arbitrary commands into system command execution. A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Affected products include: Tenda Ac500 Firmware.
Know when Ac500 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Affected is the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-261144. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
OS command injection occurs when an application passes unsanitized user input directly into system shell commands.
Affected Products (CPE)NVD
More in Ac500 Firmware
View allTenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo fun
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this vulnerability is remote
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInte
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInt
A buffer overflow vulnerability in A vulnerability (CVSS 8.8). Risk factors: public PoC available.
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVS
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid. Rated high
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. Rated medium
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this
NVD
CVE.org
EPSS
GitHub
VulDB
Exploit-DB