A vulnerability was found in Tenda AC500 2.0.1.9(1307). It has been declared as critical. Affected by this vulnerability is the function formSetAPCfg of the file /goform/setWtpData. The manipulation of the argument radio_2g_1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
AnalysisAI
A buffer overflow vulnerability in A vulnerability (CVSS 8.8). Risk factors: public PoC available.
Technical ContextAI
CWE-119 (Buffer Overflow). CVSS 8.8 indicates high severity. Affects A vulnerability.
RemediationAI
Monitor vendor channels for patch availability. Consider network segmentation to limit exposure if patching is delayed.
More in Ac500 Firmware
View allTenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo fun
A vulnerability classified as critical has been found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8),
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this vulnerability is remote
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromAddressNat via parameters entrys and mitInte
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInt
A vulnerability, which was classified as critical, has been found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVS
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e
A vulnerability was found in Tenda AC500 2.0.1.9(1307). Rated high severity (CVSS 8.8), this vulnerability is remotely e
Tenda AC500 V2.0.1.9(1307) is vulnerable to Buffer Overflow in function formOneSsidCfgSet via parameter ssid. Rated high
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. Rated medium
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone
A vulnerability classified as critical was found in Tenda AC500 2.0.1.9(1307). Rated critical severity (CVSS 9.8), this
Same weakness CWE-119 – Buffer Overflow
View allSame technique Buffer Overflow
View allShare
External POC / Exploit Code
Leaving vuln.today
EUVD-2025-21324