CVE-2024-23921

HIGH
2025-01-31 [email protected]
8.8
CVSS 3.1
Share

CVSS Vector

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Adjacent
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
Analysis Generated
Mar 28, 2026 - 18:06 vuln.today
CVE Published
Jan 31, 2025 - 01:15 nvd
HIGH 8.8

Description

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the wlanapp module. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root.

Analysis

This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Rated high severity (CVSS 8.8), this vulnerability is no authentication required, low attack complexity. No vendor patch available.

Technical Context

This vulnerability is classified as Code Injection (CWE-94), which allows attackers to inject and execute arbitrary code within the application. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the wlanapp module. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Affected products include: Chargepoint Home Flex Nema 14-50 Plug Firmware, Chargepoint Home Flex Hardwired Firmware, Chargepoint Home Flex Nema 6-50 Plug Firmware.

Affected Products

Chargepoint Home Flex Nema 14-50 Plug Firmware, Chargepoint Home Flex Hardwired Firmware, Chargepoint Home Flex Nema 6-50 Plug Firmware.

Remediation

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Never evaluate user-controlled input as code. Use sandboxing, disable dangerous functions, apply strict input validation.