Skip to main content

Labview CVE-2024-23610

HIGH
Out-of-bounds Write (CWE-787)
2024-03-11 security@ni.com
7.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, write limits
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.8 (HIGH). Attack characteristics: local attack vector, low complexity, low privileges required, no user interaction not required.

Exploit ScenarioDerived

A local attacker with access to the system could write data beyond allocated buffer boundaries leading to code execution or crashes.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
Patch available 0.6% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Rated high severity (CVSS 7.8), this vulnerability is low attack complexity. This Out-of-bounds Write vulnerability could allow attackers to write data beyond allocated buffer boundaries leading to code execution or crashes.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. Affected products include: Ni Labview.

Know when Labview gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.8 HIGH
AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Local
Attack Complexity
Low
Privileges Required
Low
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

An out of bounds write due to a missing bounds check in LabVIEW may result in remote code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions.

Threat Intelligence Overview

EPSS Score
0.6%
Top 56% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.6%
Patch available Yes
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

40
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +39
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Memory corruption occurs when a program writes data beyond the boundaries of allocated memory regions or accesses memory in unintended ways, violating the integrity of the process's address space.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)NVD

cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2021:-:*:*:-:*:*:*
cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2023:q3_patch1:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*
cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*
CVE-2017-2775 HIGH POC
7.5 Mar 31

An exploitable memory corruption vulnerability exists in the LvVariantUnflatten functionality in 64-bit versions of LabV

CVE-2017-2779 HIGH POC
7.5 Sep 05

An exploitable memory corruption vulnerability exists in the RSRC segment parsing functionality of LabVIEW 2017, LabVIEW

CVE-2013-5022 CRITICAL
10.0 Aug 06

Absolute path traversal vulnerability in the 3D Graph ActiveX control in cw3dgrph.ocx in National Instruments LabWindows

CVE-2013-5021 CRITICAL
9.3 Aug 06

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWi

CVE-2026-64204 HIGH
8.5 Aug 25

Memory corruption in NI LabVIEW 2026 Q3 (26.3.0) and all prior versions enables information disclosure or arbitrary code

CVE-2026-64203 HIGH
8.5 Aug 25

Memory corruption in NI LabVIEW 2026 Q3 (26.3.0) and all prior versions enables information disclosure or arbitrary code

CVE-2026-64202 HIGH
8.5 Aug 25

Memory corruption in NI LabVIEW 2026 Q3 (26.3.0) and all prior versions enables information disclosure or arbitrary code

CVE-2026-64201 HIGH
8.5 Aug 25

Memory corruption in NI LabVIEW (all versions through 26.3.0) enables information disclosure or arbitrary code execution

CVE-2026-16234 HIGH
8.5 Aug 25

Memory corruption in NI LabVIEW 26.3.0 and all prior versions enables information disclosure or arbitrary code execution

CVE-2026-16233 HIGH
8.5 Aug 25

Memory corruption in NI LabVIEW 2026 Q3 (26.3.0) and all prior versions enables information disclosure or arbitrary code

CVE-2025-2632 HIGH
8.5 Apr 09

Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW reading CPU info from cache that may res

CVE-2025-2631 HIGH
8.5 Apr 09

Out of bounds write vulnerability due to improper bounds checking in NI LabVIEW in InitCPUInformation() that may result

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy