Ac18 Firmware
CVE-2023-38823
CRITICAL
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Buffer copy size validation
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could overflow a buffer to corrupt adjacent memory by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Always validate buffer sizes before copy operations. Use bounded functions (strncpy, snprintf). Enable compiler protections.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Buffer Copy without Size Check (CWE-120), which allows attackers to overflow a buffer to corrupt adjacent memory. Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd. Affected products include: Tenda Ac6 Firmware, Tenda Ac9 Firmware, Tenda Ac19 Firmware, Tenda Ac18 Firmware.
Know when Ac18 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
Affected Products (CPE)NVD
More in Ac18 Firmware
View allTenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.3.10_EN was discovered to contain a stack-based buffer overflow vulnerability via the deviceId paramet
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload func
A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Rated critical severity (CVSS 9.8), thi
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function. Rated
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the entrys parameter fromAddressNat function. Rated critic
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function. Rat
Tenda AC18 v15.03.05.19(6318_)_cn was discovered to contain a command injection vulnerability via the deviceName paramet
Tenda AC18 V15.03.05.19 is vulnerable to Buffer Overflow via /goform/formWifiBasicSet. Rated critical severity (CVSS 9.8
Tenda AC18 V15.03.05.19(6318) was discovered to contain a stack overflow via the time parameter in the fromSetSysTime fu
Tenda AC18 router contained a stack overflow vulnerability in /goform/fast_setting_wifi_set. Rated critical severity (CV
NVD
CVE.org
EPSS
GitHub
Exploit-DB