Improper Authentication (CWE-287)
2022-11-11 psirt@us.ibm.com
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Nov 11, 2022 - 18:15 nvd
CRITICAL 9.8

DescriptionNVD

After performing a sequence of Power FW950, FW1010 maintenance operations a SRIOV network adapter can be improperly configured leading to desired VEPA configuration being disabled. IBM X-Force ID: 229695.

AnalysisAI

After performing a sequence of Power FW950, FW1010 maintenance operations a SRIOV network adapter can be improperly configured leading to desired VEPA configuration being disabled. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Improper Authentication (CWE-287), which allows attackers to bypass authentication mechanisms to gain unauthorized access. After performing a sequence of Power FW950, FW1010 maintenance operations a SRIOV network adapter can be improperly configured leading to desired VEPA configuration being disabled. IBM X-Force ID: 229695. Affected products include: Ibm Powervm Hypervisor.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement multi-factor authentication, enforce strong password policies, use proven authentication frameworks.

CVE-2021-38917 CRITICAL
9.1 Dec 10

IBM PowerVM Hypervisor FW860, FW940, and FW950 could allow an attacker that gains service access to the FSP can read and

CVE-2026-18821 HIGH
8.8 Aug 19

Remote code execution in IBM PowerVM Hypervisor partition firmware exposes Power Systems environments during network boo

CVE-2026-17414 HIGH
8.8 Aug 19

Network boot exploitation in IBM PowerVM Hypervisor across firmware branches FW950, FW1060, FW1110, and FW1120 allows an

CVE-2023-30438 HIGH
8.8 May 17

An internally discovered vulnerability in PowerVM on IBM Power9 and Power10 systems could allow an attacker with privile

CVE-2026-17091 HIGH
8.4 Aug 19

IBM PowerVM Hypervisor across four firmware trains (FW950 through FW1120) exposes an integer overflow (CWE-190) in its h

CVE-2026-11885 HIGH
8.4 Jul 30

OS memory integrity compromise and hypervisor denial of service in IBM PowerVM Hypervisor (firmware FW950, FW1060, and F

CVE-2026-16661 HIGH
8.2 Aug 19

Remote code execution in IBM PowerVM Hypervisor firmware versions FW950 through FW1120 allows an attacker with authentic

CVE-2023-30440 HIGH
7.9 May 23

IBM PowerVM Hypervisor FW860.00 through FW860.B3, FW950.00 through FW950.70, FW1010.00 through FW1010.50, FW1020.00 thro

CVE-2023-25683 HIGH
7.5 Jun 15

IBM PowerVM Hypervisor FW950.00 through FW950.71, FW1010.00 through FW1010.40, FW1020.00 through FW1020.20, and FW1030.0

CVE-2026-18871 HIGH
7.3 Aug 19

Stack-based buffer overflow in IBM PowerVM Hypervisor's host firmware configuration parsing allows authenticated service

CVE-2026-17097 MEDIUM
6.7 Aug 19

IBM PowerVM Hypervisor across firmware branches FW950 through FW1120 exposes a flaw in the hypervisor call (hcall) inter