Sitemanager 1129 Firmware
CVE-2022-25785
HIGH
Vulnerability Assessment
| Weakness |
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Stack buffer bounds checking
MITRE ATT&CK
1 technique across 1 tactic: Execution The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.2 (HIGH). Attack characteristics: network attack vector, low complexity, high privileges required, no user interaction not required. |
| Exploit ScenarioDerived | This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. Rated high severity (CVSS 7.2), this vulnerability is remotely exploitable, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified under CWE-121. Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7. Affected products include: Secomea Sitemanager 1129 Firmware, Secomea Sitemanager 1139 Firmware, Secomea Sitemanager 1149 Firmware, Secomea Sitemanager 3329 Firmware, Secomea Sitemanager 3339 Firmware. Version information: prior to 9.7..
Know when Sitemanager 1129 Firmware gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
Stack-based Buffer Overflow vulnerability in SiteManager allows logged-in or local user to cause arbitrary code execution. This issue affects: Secomea SiteManager all versions prior to 9.7.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.
A stack-based buffer overflow occurs when a program writes more data to a buffer located on the stack than it was allocated to hold.
Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.
Affected Products (CPE)NVD
More in Sitemanager 1129 Firmware
View allDebug tool in Secomea SiteManager allows logged-in administrator to modify system state in an unintended manner. Rated m
Cross-site Scripting (XSS) vulnerability in Web GUI of SiteManager allows logged-in user to inject scripting. Rated medi
NVD
CVE.org
EPSS
GitHub PoC