Ata 190 Firmware
CVE-2022-20688
MEDIUM
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Lifecycle Timeline
1DescriptionNVD
A vulnerability in the Cisco Discovery Protocol functionality of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device and cause Cisco Discovery Protocol service to restart. This vulnerability is due to missing length validation of certain Cisco Discovery Protocol packet header fields. An attacker could exploit these vulnerabilities by sending a malicious Cisco Discovery Protocol packet to an affected device. A successful exploit could allow the attacker to execute code on the affected device and cause Cisco Discovery Protocol to restart unexpectedly, resulting in a DoS condition.
AnalysisAI
A vulnerability in the Cisco Discovery Protocol functionality of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an unauthenticated, remote attacker to execute arbitrary code on an. Rated medium severity (CVSS 5.3), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
Technical ContextAI
This vulnerability is classified as Out-of-bounds Read (CWE-125), which allows attackers to read data from memory outside the intended buffer boundaries. A vulnerability in the Cisco Discovery Protocol functionality of Cisco ATA 190 Series Analog Telephone Adapter firmware could allow an unauthenticated, remote attacker to execute arbitrary code on an affected device and cause Cisco Discovery Protocol service to restart. This vulnerability is due to missing length validation of certain Cisco Discovery Protocol packet header fields. An attacker could exploit these vulnerabilities by sending a malicious Cisco Discovery Protocol packet to an affected device. A successful exploit could allow the attacker to execute code on the affected device and cause Cisco Discovery Protocol to restart unexpectedly, resulting in a DoS condition. Affected products include: Cisco Ata 190 Firmware, Cisco Ata 191 Firmware, Cisco Ata 192 Firmware.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate array indices and buffer lengths. Use memory-safe languages. Enable AddressSanitizer during testing.
More in Ata 190 Firmware
View allMultiple vulnerabilities in the Cisco Discovery Protocol functionality of Cisco ATA 190 Series Analog Telephone Adapter
Multiple vulnerabilities in the Cisco Discovery Protocol functionality of Cisco ATA 190 Series Analog Telephone Adapter
Multiple vulnerabilities in the Cisco ATA 190 Series Analog Telephone Adapter Software could allow an attacker to perfor
Multiple vulnerabilities in the Cisco ATA 190 Series Analog Telephone Adapter Software could allow an attacker to perfor
A vulnerability in the Cisco Discovery Protocol functionality of Cisco ATA 190 Series Adaptive Telephone Adapter firmwar
Multiple vulnerabilities in the Link Layer Discovery Protocol (LLDP) functionality of Cisco ATA 190 Series Analog Teleph
Multiple vulnerabilities in the Link Layer Discovery Protocol (LLDP) functionality of Cisco ATA 190 Series Analog Teleph
Same weakness CWE-125 – Out-of-bounds Read
View allSame technique Information Disclosure
View allShare
External POC / Exploit Code
Leaving vuln.today