Skip to main content
View

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Heap buffer bounds checking
MITRE ATT&CK

1 technique across 1 tactic: Execution

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 6.7 (MEDIUM). Attack characteristics: local attack vector, low complexity, high privileges required, no user interaction not required.

Exploit ScenarioDerived

Successful exploitation could compromise the medium-severity affected system.

This Month Plan within 30 days. Why: MEDIUM severity (CVSS 4.0-6.9).
No patch listed yet 0.3% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. Rated medium severity (CVSS 6.7), this vulnerability is low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-122. Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment. Affected products include: Dell Poweredge R640 Firmware, Dell Poweredge R740 Firmware, Dell Poweredge R740Xd Firmware, Dell Poweredge R940 Firmware, Dell Poweredge R840 Firmware.

Know when Poweredge R740 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 6.7 MEDIUM
AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Local
Attack Complexity
Low
Privileges Required
High
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionNVD

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a heap-based buffer overflow vulnerability in systems with NVDIMM-N installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

Threat Intelligence Overview

EPSS Score
0.3%
Top 77% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity MEDIUM
CISA KEV No
Public POC No
EPSS 0.3%
Patch available No
Active threat No
Deciding rule
MEDIUM severity (CVSS 4.0-6.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

34
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +34
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

A heap overflow occurs when a program writes data beyond the bounds of a buffer allocated in the heap memory region.

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Denial of Service attacks render applications or systems unavailable by overwhelming resources or triggering failure conditions.

Affected Products (CPE)NVD

cpe:2.3:o:dell:poweredge_r640_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_r740_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_r740xd_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_r940_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_r840_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_r940xa_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_t640_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_mx740c_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:poweredge_mx840c_firmware:*:*:*:*:*:*:*:*
CVE-2024-0161 HIGH
8.4 Mar 13

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an Improper SMM communication buffer verification vulner

CVE-2024-0172 HIGH
7.8 Apr 03

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper privilege management security vulnerability.

CVE-2023-32460 HIGH
7.8 Dec 08

Dell PowerEdge BIOS contains an improper privilege management security vulnerability. Rated high severity (CVSS 7.8), th

CVE-2023-25537 HIGH
7.8 May 22

Dell PowerEdge 14G server BIOS versions prior to 2.18.1 and Dell Precision BIOS versions prior to 2.18.2, contain an Out

CVE-2021-21557 MEDIUM
6.7 Jun 14

Dell PowerEdge Server BIOS and select Dell Precision Rack BIOS contain an out-of-bounds array access vulnerability. Rate

CVE-2021-21556 MEDIUM
6.7 Jun 14

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and T640 Server BIOS contain a stack-based buffer

CVE-2021-21554 MEDIUM
6.7 Jun 14

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and, Dell Precision 7920 Rack Workstation BIOS co

CVE-2024-38304 MEDIUM
6.5 Aug 29

Dell PowerEdge Platform, 14G Intel BIOS version(s) prior to 2.22.x, contains an Access of Memory Location After End of B

CVE-2024-38303 MEDIUM
6.0 Aug 29

Dell PowerEdge Platform, 14G Intel BIOS version(s) prior to 2.22.x, contains an Improper Input Validation vulnerability.

CVE-2025-26482 MEDIUM
4.9 Sep 25

Dell PowerEdge Server BIOS and Dell iDRAC9, all versions, contains an Information Disclosure vulnerability. Rated medium

CVE-2024-0173 LOW
3.3 Mar 13

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. Rate

CVE-2024-0154 LOW
3.3 Mar 13

Dell PowerEdge Server BIOS and Dell Precision Rack BIOS contain an improper parameter initialization vulnerability. Rate

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy