Skip to main content

My Cloud Firmware CVE-2020-12830

CRITICAL
Out-of-bounds Write (CWE-787)
2020-10-27 cve@mitre.org
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Oct 27, 2020 - 20:15 nvd
CRITICAL 9.8

DescriptionNVD

Addressed multiple stack buffer overflow vulnerabilities that could allow an attacker to carry out escalation of privileges through unauthorized remote code execution in Western Digital My Cloud devices before 5.04.114.

AnalysisAI

Addressed multiple stack buffer overflow vulnerabilities that could allow an attacker to carry out escalation of privileges through unauthorized remote code execution in Western Digital My Cloud. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Out-of-bounds Write (CWE-787), which allows attackers to write data beyond allocated buffer boundaries leading to code execution or crashes. Addressed multiple stack buffer overflow vulnerabilities that could allow an attacker to carry out escalation of privileges through unauthorized remote code execution in Western Digital My Cloud devices before 5.04.114. Affected products include: Westerndigital My Cloud Firmware. Version information: before 5.04.114..

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate write boundaries, use memory-safe languages, enable compiler protections (ASLR, stack canaries).

CVE-2020-27744 CRITICAL POC
9.8 Oct 29

An issue was discovered on Western Digital My Cloud NAS devices before 5.04.114. Rated critical severity (CVSS 9.8), thi

CVE-2020-27160 CRITICAL POC
9.8 Oct 27

Addressed remote code execution vulnerability in AvailableApps.php that allowed escalation of privileges in Western Digi

CVE-2020-27159 CRITICAL POC
9.8 Oct 27

Addressed remote code execution vulnerability in DsdkProxy.php due to insufficient sanitization and insufficient validat

CVE-2020-27158 CRITICAL POC
9.8 Oct 27

Addressed remote code execution vulnerability in cgi_api.php that allowed escalation of privileges in Western Digital My

CVE-2020-25765 CRITICAL POC
9.8 Oct 27

Addressed remote code execution vulnerability in reg_device.php due to insufficient validation of user input.in Western

CVE-2018-9148 CRITICAL POC
9.8 Mar 30

Western Digital WD My Cloud v04.05.00-320 devices embed the session token (aka PHPSESSID) in filenames, which makes it e

CVE-2019-9949 HIGH POC
8.8 May 23

Western Digital My Cloud Cloud, Mirror Gen2, EX2 Ultra, EX2100, EX4100, DL2100, DL4100, PR2100 and PR4100 before firmwar

CVE-2022-22995 CRITICAL
9.8 Mar 25

The combination of primitives offered by SMB and AFP in their default configuration allows the arbitrary writing of file

CVE-2019-9951 CRITICAL
9.8 Apr 24

Western Digital My Cloud, My Cloud Mirror Gen2, My Cloud EX2 Ultra, My Cloud EX2100, My Cloud EX4100, My Cloud DL2100, M

CVE-2019-9950 CRITICAL
9.8 Apr 24

Western Digital My Cloud, My Cloud Mirror Gen2, My Cloud EX2 Ultra, My Cloud EX2100, My Cloud EX4100, My Cloud DL2100, M

CVE-2022-23000 HIGH
7.8 Jul 25

The Western Digital My Cloud Web App [https://os5.mycloud.com/] uses a weak SSLContext when attempting to configure port