Factorytalk Linx
CVE-2020-12003
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A01:2025 - Broken Access Control
ASVS 5.0
V5 - File Handling Path canonicalization, traversal prevention
MITRE ATT&CK
2 techniques across 2 tactics: Discovery, Collection The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could access files and directories outside the intended path by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate and canonicalize file paths. Use chroot or sandboxing. Reject input containing path separators or '../' sequences.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Path Traversal (CWE-22), which allows attackers to access files and directories outside the intended path. FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive. Affected products include: Rockwellautomation Factorytalk Linx, Rockwellautomation Rslinx Classic. Version information: Version 12.
Know when Factorytalk Linx gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Path traversal exploits occur when applications use user-controlled input to construct file system paths without proper validation.
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
Affected Products (CPE)NVD
More in Factorytalk Linx
View allA heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. Rated critical severity (CVSS 9.8),
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from me
Local privilege escalation in Rockwell Automation's FactoryTalk Linx Driver Package (x64 Microsoft Installer) allows an
Local privilege escalation in Rockwell Automation FactoryTalk Linx allows an authenticated Windows user to obtain SYSTEM
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio
An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a special
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled ex
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. Rated high severity (CVSS 7.5), thi
A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. Rated high severity (CVSS
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio
An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseL
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB