Factorytalk Linx CVE-2020-5801

HIGH
Improper Handling of Exceptional Conditions (CWE-755)
2020-12-29 vulnreport@tenable.com
7.5
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A10:2025 - Mishandling of Exceptional Conditions
ASVS 5.0
V16 - Security Logging and Error Handling Exception handling procedures
Impact

CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required.

Exploit ScenarioDerived

This vulnerability can be exploited remotely over the network. Successful exploitation could compromise the high-severity affected system.

This Week Schedule remediation this week. Why: HIGH severity + EPSS > 10%.
No patch listed yet 25.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified under CWE-755. An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected. Affected products include: Rockwellautomation Factorytalk Linx.

Know when Factorytalk Linx gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.5 HIGH
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
None
Integrity
None
Availability
High

DescriptionNVD

An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.

Threat Intelligence Overview

EPSS Score
25.2%
Top 2% exploitable
Data Quality
2 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 25.2%
Patch available No
Active threat No
Deciding rule
HIGH severity + EPSS > 10%
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

63
Low Medium High Critical
KEV: 0
EPSS: +25
CVSS: +38
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.

Affected Products (CPE)NVD

cpe:2.3:a:rockwellautomation:factorytalk_linx:*:*:*:*:*:*:*:*
CVE-2020-27251 CRITICAL
9.8 Nov 26

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. Rated critical severity (CVSS 9.8),

CVE-2020-12001 CRITICAL
9.8 Jun 15

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio

CVE-2023-29464 CRITICAL
9.1 Oct 13

FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from me

CVE-2025-9068 HIGH
8.5 Oct 14

Local privilege escalation in Rockwell Automation's FactoryTalk Linx Driver Package (x64 Microsoft Installer) allows an

CVE-2025-9067 HIGH
8.5 Oct 14

Local privilege escalation in Rockwell Automation FactoryTalk Linx allows an authenticated Windows user to obtain SYSTEM

CVE-2020-11999 HIGH
8.1 Jun 15

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio

CVE-2020-5802 HIGH
7.5 Dec 29

An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a special

CVE-2020-27255 HIGH
7.5 Nov 26

A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. Rated high severity (CVSS 7.5), thi

CVE-2020-27253 HIGH
7.5 Nov 26

A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. Rated high severity (CVSS

CVE-2020-12005 HIGH
7.5 Jun 15

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio

CVE-2020-12003 HIGH
7.5 Jun 15

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio

CVE-2020-5806 MEDIUM
5.5 Dec 29

An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseL

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy