Factorytalk Linx
CVE-2020-12005
HIGH
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V5 - File Handling File type validation, storage isolation
MITRE ATT&CK
2 techniques across 2 tactics: Command and Control, Persistence The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up. |
| Impact | CVSS score of 7.5 (HIGH). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. |
| Exploit ScenarioDerived | A remote attacker could upload malicious files that can be executed on the server by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAI
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version. Rated high severity (CVSS 7.5), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.
RemediationAI
No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Validate file types server-side, store uploads outside webroot, use random filenames, scan for malware.
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
This vulnerability is classified as Unrestricted File Upload (CWE-434), which allows attackers to upload malicious files that can be executed on the server. FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition. Affected products include: Rockwellautomation Factorytalk Linx, Rockwellautomation Rslinx Classic. Version information: Version 12.
Know when Factorytalk Linx gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Primary rating from NVD · only source for this CVE.
CVSS VectorNVD
DescriptionNVD
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Malicious file upload attacks exploit insufficient validation when web applications accept user-provided files.
Affected Products (CPE)NVD
More in Factorytalk Linx
View allA heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. Rated critical severity (CVSS 9.8),
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from me
Local privilege escalation in Rockwell Automation's FactoryTalk Linx Driver Package (x64 Microsoft Installer) allows an
Local privilege escalation in Rockwell Automation FactoryTalk Linx allows an authenticated Windows user to obtain SYSTEM
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio
An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a special
An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled ex
A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. Rated high severity (CVSS 7.5), thi
A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. Rated high severity (CVSS
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Versio
An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseL