Skip to main content

Severity by source

NVD PRIMARY
3.4 LOW
AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N
Attack Vector
Network
Attack Complexity
High
Privileges Required
None
User Interaction
Required
Scope
Changed
Confidentiality
Low
Integrity
None
Availability
None

Lifecycle Timeline

1
CVE Published
Aug 05, 2017 - 17:29 cve.org
LOW 3.4

DescriptionCVE.org

An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device. NOTE: the vendor reports that only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

AnalysisAI

An issue was discovered in SMA Solar Technology products. Rated low severity (CVSS 3.4), this vulnerability is remotely exploitable, no authentication required. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-256. An issue was discovered in SMA Solar Technology products. Sniffed passwords from SMAdata2+ communication can be decrypted very easily. The passwords are "encrypted" using a very simple encryption algorithm. This enables an attacker to find the plaintext passwords and authenticate to the device. NOTE: the vendor reports that only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected Affected products include: Sma Sunny Boy 3600 Firmware, Sma Sunny Boy 5000 Firmware, Sma Sunny Tripower Core1 Firmware, Sma Sunny Tripower 15000Tl Firmware, Sma Sunny Tripower 20000Tl Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2017-9860 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9855 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9853 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9852 CRITICAL
9.8 Aug 05

An Incorrect Password Management issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.

CVE-2017-9854 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9859 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9861 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9863 HIGH
8.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 8.8), this vulnerability is remotely

CVE-2017-9857 HIGH
8.1 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 8.1), this vulnerability is remotely

CVE-2017-9858 HIGH
7.5 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 7.5), this vulnerability is remotely

CVE-2017-9864 HIGH
7.5 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 7.5), this vulnerability is remotely

Share

CVE-2017-9856 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy