Skip to main content

Severity by source

NVD PRIMARY
8.8 HIGH
AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Aug 05, 2017 - 17:29 cve.org
HIGH 8.8

DescriptionCVE.org

An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cross-site request forgery can be used to change settings in the inverters (for example, issuing a POST request to change the user password). All Sunny Explorer settings available to the authenticated user are also available to the attacker. (In some cases, this also includes changing settings that the user has no access to.) This may result in complete compromise of the device. NOTE: the vendor reports that exploitation is unlikely because Sunny Explorer is used only rarely. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

AnalysisAI

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 8.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Cross-Site Request Forgery (CSRF) (CWE-352), which allows attackers to trick authenticated users into performing unintended actions. An issue was discovered in SMA Solar Technology products. If a user simultaneously has Sunny Explorer running and visits a malicious host, cross-site request forgery can be used to change settings in the inverters (for example, issuing a POST request to change the user password). All Sunny Explorer settings available to the authenticated user are also available to the attacker. (In some cases, this also includes changing settings that the user has no access to.) This may result in complete compromise of the device. NOTE: the vendor reports that exploitation is unlikely because Sunny Explorer is used only rarely. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected Affected products include: Sma Sunny Boy 3600 Firmware, Sma Sunny Boy 5000 Firmware, Sma Sunny Tripower Core1 Firmware, Sma Sunny Tripower 15000Tl Firmware, Sma Sunny Tripower 20000Tl Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Implement anti-CSRF tokens, validate Origin/Referer headers, use SameSite cookie attribute.

CVE-2017-9860 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9855 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9853 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9852 CRITICAL
9.8 Aug 05

An Incorrect Password Management issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.

CVE-2017-9854 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9859 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9861 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9857 HIGH
8.1 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 8.1), this vulnerability is remotely

CVE-2017-9858 HIGH
7.5 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 7.5), this vulnerability is remotely

CVE-2017-9864 HIGH
7.5 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 7.5), this vulnerability is remotely

CVE-2017-9856 LOW
3.4 Aug 05

An issue was discovered in SMA Solar Technology products. Rated low severity (CVSS 3.4), this vulnerability is remotely

Share

CVE-2017-9863 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy