Skip to main content

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Aug 05, 2017 - 17:29 cve.org
CRITICAL 9.8

DescriptionCVE.org

An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

AnalysisAI

An Incorrect Password Management issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified as Use of Hard-coded Credentials (CWE-798), which allows attackers to gain access using credentials embedded in source code. An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected Affected products include: Sma Sunny Boy 3600 Firmware, Sma Sunny Boy 5000 Firmware, Sma Sunny Tripower Core1 Firmware, Sma Sunny Tripower 15000Tl Firmware, Sma Sunny Tripower 20000Tl Firmware.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Remove hard-coded credentials, use environment variables or secrets management, rotate exposed credentials immediately.

CVE-2017-9860 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9855 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9853 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9854 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9859 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9861 CRITICAL
9.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated critical severity (CVSS 9.8), this vulnerability is remo

CVE-2017-9863 HIGH
8.8 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 8.8), this vulnerability is remotely

CVE-2017-9857 HIGH
8.1 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 8.1), this vulnerability is remotely

CVE-2017-9858 HIGH
7.5 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 7.5), this vulnerability is remotely

CVE-2017-9864 HIGH
7.5 Aug 05

An issue was discovered in SMA Solar Technology products. Rated high severity (CVSS 7.5), this vulnerability is remotely

CVE-2017-9856 LOW
3.4 Aug 05

An issue was discovered in SMA Solar Technology products. Rated low severity (CVSS 3.4), this vulnerability is remotely

Share

CVE-2017-9852 vulnerability details – vuln.today

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy