Attack ChainAIDerived
Hypothetical attack flow derived from CVE metadata – not a confirmed exploit chain
-
AccessObtain any local/filesystem read access
-
DeliveryLocate world-readable credential files
-
ExploitRead cleartext DB/root/SaaS/Portainer secrets
-
ExecutionAuthenticate to backend and container management
-
ImpactFull appliance and downstream compromise
Vulnerability Assessment
| Weakness |
CWE
OWASP Top 10:2025
A06:2025 - Insecure Design
ASVS 5.0
V6 - Authentication Credential storage protection
|
| Exploitation Conditions | Requires local presence on the Vasion Print VA/SaaS appliance: the attacker must be any local user on the host, or any process/account able to read the host filesystem. The specific prerequisite is that the sensitive files (database passwords, MySQL root password, SaaS keys, Portainer admin password) are stored in cleartext with world-readable permissions - which is the default per the disclosure. The primary LIMITING factor is that exploitation is local-only (no network vector) and the vendor states the risk is mitigated when administrators enable persistent-storage encryption, so deployments that have configured storage encryption per the vendor's shared-responsibility guidance materially reduce exposure. No user interaction and no elevated privileges beyond local filesystem read are needed. |
| Impact | Signals here point strongly toward low real-world urgency despite the headline CVSS 4.0 base score of 9.4. The CVSS vector is explicitly local (AV:L), not network, so this cannot be exploited remotely - the high score is driven by the HIGH vulnerable- and subsequent-system impact metrics (VC/VI/VA and SC/SI/SA all H), reflecting that harvested database, MySQL root, SaaS, and Portainer credentials enable full appliance and downstream compromise once an attacker is already on the host. EPSS is 0.01% (1st percentile), among the lowest possible, which is consistent with a local-only information-disclosure bug that offers no mass-scannable, remotely automatable surface. This CVE is NOT in CISA KEV, so there is no confirmed active exploitation; POC exploit code is publicly available (Pierre Kim's detailed disclosure), but POC availability is a distinct signal from in-the-wild use and should not be conflated with it. A notable conflict to flag: the vendor formally DISPUTES this as a vulnerability, arguing a shared-responsibility model where administrators are expected to enable persistent-storage encryption - so defenders must independently decide whether their deployment matches the vendor's assumed configuration. Net assessment: real but conditional risk - meaningful as a privilege-escalation/post-compromise amplifier (any local foothold becomes full appliance and credential-chain compromise), not a remote entry point or patch-now emergency. |
| Exploit ScenarioDerived | An attacker who already has any local account on the Vasion Print virtual appliance - or any process able to read the host filesystem (e.g., a low-privilege service, a chained prior bug, or a malicious insider) - reads the world-readable cleartext files and harvests database passwords, the MySQL root password, SaaS keys, and the Portainer admin password. Using those recovered secrets, they pivot to full control of the appliance and connected backend/SaaS services. Publicly available POC/disclosure details the exact readable file locations, lowering the effort required. |
Get an e-mail when this CVE is exploited, patched or re-scored. Free account.
Alert meAnalysisAIv2 – Oct 18, 2026
Cleartext storage of database, SaaS, and administrative credentials in Vasion Print (formerly PrinterLogic) virtual appliance host and application deployments lets any local user or filesystem-reading process recover secrets and fully compromise the appliance. The issue is local-only and requires filesystem read access, but publicly available exploit code exists, no CISA KEV entry appears in the supplied data, and EPSS is 0.01% (1st percentile). The vendor does not consider it a vulnerability and instead points to persistent-storage encryption under a shared-responsibility model, so no vendor-released patch is identified.
Earlier versions of this analysis (1)
Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA/SaaS deployments) store a large number of sensitive credentials (database passwords, MySQL root password, SaaS keys, Por
RemediationAI
No vendor-released patch is identified at time of analysis; the vendor's position is that exposure is addressed by enabling persistent-storage encryption under a shared-responsibility model. Administrators should enable that encryption if not already active, accepting key-management and potential performance overhead, and should treat it as the primary control. Rotate every credential that may have been stored in cleartext, including database passwords, the MySQL root password, SaaS keys, and the Portainer admin password, accepting service downtime and coordination. Restrict local logon and filesystem read access to trusted administrators and service accounts through OS permissions or ACLs, testing carefully because overly tight ACLs can break appliance services. Audit world-readable files and monitor local access, then consult the vendor security bulletins at https://help.printerlogic.com/va/Print/Security/Security-Bulletins.htm and https://help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm for updates.
Affected VersionsENISA
Affects your stack
Find out whether the stacks and servers you run are on an affected version.
Checking this CVE against your own stacks and servers is part of the Basic plan and up.
Technical ContextAI · show details
CWE-256 (Plaintext Storage of a Password) is the root cause: Vasion Print's Virtual Appliance Host and Application components place database passwords, the MySQL root password, SaaS keys, the Portainer admin password, and other secrets in cleartext files with world-readable permissions. The CPEs identify both the host and application layers, so exposure spans the appliance OS and the print-management application. Exploitation requires local presence on the appliance, or a process/account able to read the host filesystem; it is not network-reachable by itself. The assessed vector is local, low-complexity, scope-changed, with high confidentiality, integrity, and availability impact because recovered credentials can yield full appliance compromise. The vendor states that persistent-storage encryption, when configured by administrators, materially reduces the risk; deployments without that control are the most exposed.
Know when Virtual Appliance Host gets its next vulnerability
- Watch products and get an email when something new is published
- Check this CVE against your own stack and servers
- Exploit and PoC references, threat intelligence from 22 sources
No credit card · 7-day full trial
Severity by source
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
Local-only (AV:L) read by any low-privilege local user (PR:L) of world-readable cleartext secrets; harvested credentials compromise other components, so scope changes (S:C) with full C/I/A impact.
Primary rating from Vendor (vulncheck).
CVSS VectorVendor: vulncheck
Lifecycle Timeline
5DescriptionCVE.org
Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA/SaaS deployments) store a large number of sensitive credentials (database passwords, MySQL root password, SaaS keys, Portainer admin password, etc.) in cleartext files that are world-readable. Any local user - or any process that can read the host filesystem - can retrieve all of these secrets in plain text, leading to credential theft and full compromise of the appliance. The vendor does not consider this to be a security vulnerability as this product "follows a shared responsibility model, where administrators are expected to configure persistent storage encryption."
Executive ViewAI
Leadership should treat the Vasion Print (formerly PrinterLogic) virtual appliance as a high-value credential store whose local access model can expose the organization to full appliance takeover if filesystem permissions are weak. Organizations with broad local administrative access, shared backup access, or unencrypted persistent storage are most exposed, because recovered secrets could extend into connected SaaS integrations and administrative accounts. The issue is local-only, but publicly available exploit code exists, so reducing local footholds and rotating stored secrets should be prioritized.
No vendor-released patch identified at time of analysis; restrict local shell and filesystem access to trusted administrators, enable persistent-storage encryption per vendor guidance, rotate all appliance-stored database, SaaS, and administrative credentials, isolate the appliance on a restricted management network, secure backups, and monitor for unauthorized local access.
Threat Intelligence Overview
How this decision was reached
The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.
What every action level means
SSVC AssessmentENISA
Priority Score
Attack Technique
Information disclosure occurs when an application unintentionally exposes sensitive data that aids attackers in reconnaissance or directly compromises security.
More in Virtual Appliance Host
View allVasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 25.2.169 and Application prior to version 2
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.843 and Application prior to 20.0.192
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1049 and Application prior to version
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 25.1.102 and Application prior to version 2
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to version 22.0.1026 and Application prior to version
Vasion Print (formerly PrinterLogic) Virtual Appliance Host prior to 22.0.862 and Application prior to 20.0.2014 (VA and
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.893 and Application versions prior to
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 22.0.951 and Application prior to 20.0.236
EUVD-2025-32645
NVD
CVE.org
EPSS
GitHub PoC
Exploit-DB