Skip to main content

Unity Pro CVE-2016-8354

HIGH
Code Injection (CWE-94)
2017-02-13 ics-cert@hq.dhs.gov
7.0
CVSS 3.0 · NVD
View

Vulnerability Assessment

Weakness
CWE
OWASP Top 10:2025
A05:2025 - Injection
ASVS 5.0
V1 - Encoding and Sanitization Code injection prevention, sandbox exec
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Initial Access

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 7.0 (HIGH). Attack characteristics: local attack vector, high complexity, no privileges required, user interaction required. EPSS exploitation probability: 0.16%.

Exploit ScenarioDerived

A local attacker with access to the system could inject and execute arbitrary code within the application. No authentication is required to exploit this vulnerability.

This Week Schedule remediation this week. Why: HIGH severity (CVSS 7.0-8.9).
No patch listed yet 0.2% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Rated high severity (CVSS 7.0), this vulnerability is no authentication required. No vendor patch available.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Never evaluate user-controlled input as code. Use sandboxing, disable dangerous functions, apply strict input validation.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Code Injection (CWE-94), which allows attackers to inject and execute arbitrary code within the application. An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions. Affected products include: Schneider-Electric Unity Pro.

Know when Unity Pro gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 7.0 HIGH
AV:L/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Local
Attack Complexity
High
Privileges Required
None
User Interaction
Required
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

DescriptionCVE.org

An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.

Threat Intelligence Overview

EPSS Score
0.2%
Top 63% exploitable
Data Quality
3 sources
Confidence: Low

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity HIGH
CISA KEV No
Public POC No
EPSS 0.2%
Patch available No
Active threat No
Deciding rule
HIGH severity (CVSS 7.0-8.9)
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Defer
Exploitation· derived
None
System Exposure· derived
Small
Automatable· derived
No
Human Impact· derived
Medium

Priority Score

35
Low Medium High Critical
KEV: 0
EPSS: 0
CVSS: +35
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

Code Injection CRITICAL

Code injection occurs when an application accepts user input and passes it directly into a language interpreter or evaluator without proper sanitization.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)CVE.org

cpe:2.3:a:schneider-electric:unity_pro:*:*:*:*:*:*:*:*

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy