Skip to main content

Ecostruxure Control Expert CVE-2020-7475

CRITICAL
Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') (CWE-74)
2020-03-23 cybersecurity@se.com
9.8
CVSS 3.1 · NVD
Share

Severity by source

NVD PRIMARY
9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

1
CVE Published
Mar 23, 2020 - 19:15 nvd
CRITICAL 9.8

DescriptionNVD

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.

AnalysisAI

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity. No vendor patch available.

Technical ContextAI

This vulnerability is classified under CWE-74. A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller. Affected products include: Schneider-Electric Ecostruxure Control Expert, Schneider-Electric Unity Pro, Schneider-Electric Modicon M340 Firmware, Schneider-Electric Modicon M580 Firmware. Version information: prior to 14.1.

RemediationAI

No vendor patch is available at time of analysis. Monitor vendor advisories for updates. Apply vendor patches when available. Implement network segmentation and monitoring as interim mitigations.

CVE-2020-7559 HIGH POC
7.5 Nov 19

A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator

CVE-2022-37300 CRITICAL
9.8 Sep 12

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized ac

CVE-2022-26507 CRITICAL
9.8 Apr 14

A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. Rated critical severity

CVE-2020-28212 CRITICAL
9.8 Nov 19

A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists in PLC Simulator on EcoStruxur

CVE-2021-22779 CRITICAL
9.1 Jul 14

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, i

CVE-2023-27976 HIGH
8.8 Apr 18

A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid

CVE-2020-28213 HIGH
8.8 Nov 19

A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert

CVE-2020-7560 HIGH
8.6 Dec 11

A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (

CVE-2020-28211 HIGH
7.8 Nov 19

A CWE-863: Incorrect Authorization vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro)

CVE-2020-7538 HIGH
7.5 Nov 19

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Co

CVE-2021-22780 HIGH
7.1 Jul 14

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1

CVE-2021-22778 HIGH
7.1 Jul 14

Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1

Share

CVE-2020-7475 vulnerability details – vuln.today