Skip to main content

Micrologix 1100 Firmware CVE-2015-6490

CRITICAL
Buffer Overflow (CWE-119)
2015-10-28 ics-cert@hq.dhs.gov
9.8
CVSS 3.1 · NVD
View

Vulnerability Assessment

Weakness
CWE
ASVS 5.0
V15 - Secure Coding and Architecture Bounds checking, buffer size validation
MITRE ATT&CK

2 techniques across 2 tactics: Execution, Privilege Escalation

The technique list with ATT&CK links and the kill-chain view is part of the Basic plan and up.

Impact

CVSS score of 9.8 (CRITICAL). Attack characteristics: network attack vector, low complexity, no privileges required, no user interaction not required. EPSS exploitation probability: 1.42%.

Exploit ScenarioDerived

A remote attacker could corrupt memory to execute arbitrary code or crash the application by sending crafted requests to the affected application. No authentication is required to exploit this vulnerability.

Act Now Prioritize within 24-48h. Why: CRITICAL severity.
Patch available 1.4% exploitation probability (EPSS)

Get an e-mail when this CVE is exploited, patched or re-scored. Free account.

Alert me

AnalysisAI

Stack-based buffer overflow on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices through B FRN 15.003 allows remote attackers to execute arbitrary code via unspecified. Rated critical severity (CVSS 9.8), this vulnerability is remotely exploitable, no authentication required, low attack complexity.

RemediationAI

A vendor patch is available. Apply the latest security update as soon as possible. Use memory-safe languages or bounds-checking. Enable ASLR, DEP/NX, stack canaries. Use safe string functions.

Affects your stack

Find out whether the stacks and servers you run are on an affected version.

Checking this CVE against your own stacks and servers is part of the Basic plan and up.

Technical ContextAI · show details

This vulnerability is classified as Buffer Overflow (CWE-119), which allows attackers to corrupt memory to execute arbitrary code or crash the application. Stack-based buffer overflow on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices through B FRN 15.003 allows remote attackers to execute arbitrary code via unspecified vectors. Affected products include: Rockwellautomation Micrologix 1100 Firmware, Rockwellautomation Micrologix 1400 Firmware.

Know when Micrologix 1100 Firmware gets its next vulnerability

  • Watch products and get an email when something new is published
  • Check this CVE against your own stack and servers
  • Exploit and PoC references, threat intelligence from 22 sources

No credit card · 7-day full trial

Severity by source

NVD PRIMARY 9.8 CRITICAL
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Primary rating from NVD · only source for this CVE.

CVSS VectorNVD

Attack Vector
Network
Attack Complexity
Low
Privileges Required
None
User Interaction
None
Scope
Unchanged
Confidentiality
High
Integrity
High
Availability
High

Lifecycle Timeline

2
CVSS changed
Jun 03, 2026 - 14:22 NVD
10.0 (CRITICAL) 9.8 (CRITICAL)
CVE Published
Oct 28, 2015 - 10:59 cve.org
CRITICAL 9.8

DescriptionCVE.org

Stack-based buffer overflow on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices through B FRN 15.003 allows remote attackers to execute arbitrary code via unspecified vectors.

Threat Intelligence Overview

EPSS Score
1.4%
Top 19% exploitable
Data Quality
4 sources
Confidence: Medium

How this decision was reached

The engine reads each signal below and applies a fixed list of rules from top to bottom. The first rule that matches sets the recommended action – like a statement, every line is shown.

SignalValue
Severity CRITICAL
CISA KEV No
Public POC No
EPSS 1.4%
Patch available Yes
Active threat No
Deciding rule
CRITICAL severity
What every action level means
Emergency Immediate action required. Criteria: CRITICAL + in CISA KEV (actively exploited) without patch, OR CRITICAL + EPSS > 30% without patch, OR CRITICAL + active threat signals without patch.
Act Now Prioritize within 24-48h. Criteria: in KEV with patch available, OR CRITICAL + public POC, OR HIGH + EPSS > 10%, OR CRITICAL + active threat, OR any CRITICAL severity.
This Week Schedule remediation this week. Criteria: HIGH severity (CVSS 7.0-8.9). Patch within normal change window.
This Month Plan within 30 days. Criteria: MEDIUM severity (CVSS 4.0-6.9), lower exploitation probability. Include in regular patch cycle.
Monitor Track and reassess. Criteria: LOW severity (CVSS 0.1-3.9), minimal exploitation risk. No immediate action needed.

SSVC AssessmentENISA

SSVC Decision· derived
Scheduled
Exploitation· derived
None
System Exposure· derived
Open
Automatable· derived
Yes
Human Impact· derived
Medium

Priority Score

50
Low Medium High Critical
KEV: 0
EPSS: +1
CVSS: +49
PoC: 0
Weaponized: 0
Threat intel: 0
Gov advisory: 0

Attack Technique

A buffer overflow occurs when a program writes more data to a memory buffer than it was allocated to hold, causing the excess data to spill into adjacent memory regions.

Remote Code Execution represents the critical moment when an attacker successfully runs arbitrary code on a target system without physical access.

Affected Products (CPE)CVE.org

cpe:2.3:o:rockwellautomation:micrologix_1100_firmware:*:*:*:*:*:*:*:*
cpe:2.3:o:rockwellautomation:micrologix_1400_firmware:*:*:*:*:*:*:*:*
CVE-2020-6990 CRITICAL
9.8 Mar 16

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Cont

CVE-2015-6492 HIGH
7.5 Oct 28

Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote attackers to

CVE-2021-33012 HIGH
8.6 Jul 09

Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted c

CVE-2020-6984 HIGH
7.5 Mar 16

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Cont

CVE-2020-6988 HIGH
7.5 Mar 16

Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Cont

CVE-2022-3166 HIGH
7.5 Dec 16

Rockwell Automation was made aware that the webservers of the Micrologix 1100 and 1400 controllers contain a vulnerabili

CVE-2019-10955 MEDIUM
6.1 Apr 25

In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100

CVE-2015-6486 MEDIUM
6.5 Oct 28

SQL injection vulnerability on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 1

CVE-2022-2179 MEDIUM
6.5 Jul 20

The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in th

CVE-2022-46670 MEDIUM
6.1 Dec 16

Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that

CVE-2015-6488 MEDIUM
4.3 Oct 28

Cross-site scripting (XSS) vulnerability in the web server on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000

CVE-2015-6491 MEDIUM
4.0 Oct 28

Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticate

This site uses cookies essential for authentication and security. No tracking or analytics cookies are used. Privacy Policy